ITMEX2ATV-MIB DEFINITIONS ::= BEGIN
IMPORTS
it FROM IT-MIB
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, IpAddress FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP, AGENT-CAPABILITIES FROM SNMPv2-CONF
DateAndTime, DisplayString FROM SNMPv2-TC;
itmex2atv MODULE-IDENTITY
LAST-UPDATED "201910110940Z"
ORGANIZATION " ITELCO BROADCAST S.r.l., Italy "
CONTACT-INFO
"Contact:
Web: https://www.itelco.tv
Address: Via dell'innovazione 4, 05018 Orvieto (TR), Italy
Telephone: +39 0763 960300"
DESCRIPTION
"This is the MIB file of ITMEX2ATV modulator.
Copyright (c) 2018 Itelco s.r.l.(.
All rights reserved.
Reproduction of this document is authorized on the condition
that the foregoing copyright notice is included."
REVISION
"201910110940Z"
DESCRIPTION
"SWITELCOATV_P3_1_02_358 build 1615718558"
::= { it 39 }
itmex2atvSystem OBJECT IDENTIFIER ::= { itmex2atv 1 }
itmex2atvAtv OBJECT IDENTIFIER ::= { itmex2atv 2 }
itmex2atvInput OBJECT IDENTIFIER ::= { itmex2atv 3 }
itmex2atvOutput OBJECT IDENTIFIER ::= { itmex2atv 4 }
itmex2atvGps OBJECT IDENTIFIER ::= { itmex2atv 7 }
itmex2atvMonitor OBJECT IDENTIFIER ::= { itmex2atv 12 }
itmex2atvTest OBJECT IDENTIFIER ::= { itmex2atv 13 }
itmex2atvAlarm OBJECT IDENTIFIER ::= { itmex2atv 14 }
itmex2atvPreset OBJECT IDENTIFIER ::= { itmex2atv 15 }
itmex2atvEventlog OBJECT IDENTIFIER ::= { itmex2atv 16 }
itmex2atvComms OBJECT IDENTIFIER ::= { itmex2atv 17 }
itmex2atvPrecorrector OBJECT IDENTIFIER ::= { itmex2atv 25 }
itmex2atvBackplane OBJECT IDENTIFIER ::= { itmex2atv 27 }
itmex2atvNotifs OBJECT IDENTIFIER ::= { itmex2atv 64 }
itmex2atvConformance OBJECT IDENTIFIER ::= { itmex2atv 100 }
itmex2atvCompliances OBJECT IDENTIFIER ::= { itmex2atvConformance 1 }
--
--
-- itmex2atv System sub-tree
--
itmex2atvSystemInstrumentFW1Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW1 revision"
::= { itmex2atvSystem 7 }
itmex2atvSystemInstrumentFW1RevBL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW1 BL revision"
::= { itmex2atvSystem 8 }
itmex2atvSystemInstrumentFW2Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW2 revision"
::= { itmex2atvSystem 9 }
itmex2atvSystemInstrumentFW2RevBL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW2 BL revision"
::= { itmex2atvSystem 10 }
itmex2atvSystemInstrumentFW3Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW3 revision"
::= { itmex2atvSystem 11 }
itmex2atvSystemInstrumentFW4Rev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument FW4 revision"
::= { itmex2atvSystem 12 }
itmex2atvSystemInstrumentPCBRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument PCB revision"
::= { itmex2atvSystem 13 }
itmex2atvSystemInstrumentCalibrationRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Calibration revision"
::= { itmex2atvSystem 14 }
itmex2atvSystemInstrumentCalibrationDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Calibration date"
::= { itmex2atvSystem 15 }
itmex2atvSystemReboot OBJECT-TYPE
SYNTAX INTEGER { keeprunning(0), sameimage(1), otherimage(2), image0(3), image1(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force a reboot of the device on the designated image now."
::= { itmex2atvSystem 16 }
itmex2atvSystemRebootDefaultConfig OBJECT-TYPE
SYNTAX INTEGER { keeprunning(0), reboot(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Restore all parameters to factory default and reboot the device on the same image."
::= { itmex2atvSystem 19 }
itmex2atvSystemDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current date/time in local timezone of the device.
Format is YYYY MM DD HH MM SS."
::= { itmex2atvSystem 22 }
itmex2atvSystemImage0Version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image 0 version string."
::= { itmex2atvSystem 24 }
itmex2atvSystemImage0InstalledDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time image 0 was installed."
::= { itmex2atvSystem 25 }
itmex2atvSystemImage1version OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The image 1 version string."
::= { itmex2atvSystem 26 }
itmex2atvSystemImage1InstalledDate OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time image 0 was installed."
::= { itmex2atvSystem 27 }
itmex2atvSystemServiceLED OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control the Service LED on frontpanel."
::= { itmex2atvSystem 28 }
itmex2atvSystemLanguage OBJECT-TYPE
SYNTAX INTEGER { c(0), da-dk(1), ru-ru(2), es-es(3), pt-br(4), it-it(5), de-de(6), fr-fr(7) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which language is used on web and facia. Change requires
reboot."
::= { itmex2atvSystem 33 }
itmex2atvSystemType OBJECT-TYPE
SYNTAX INTEGER { modulator(0), repeater(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system type to start in on next reboot."
::= { itmex2atvSystem 30 }
itmex2atvSystemModulationStandard OBJECT-TYPE
SYNTAX INTEGER { dvbt(0), dvbt2(1), atsc(2), isdbt(3), iboc(4), dab(5), atsc30(6), atv(7), gapfiller(8), radio(9) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Modulation Standard to start in on next reboot."
::= { itmex2atvSystem 32 }
itmex2atvSystemCurrentImage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The flash Image the device is currently booted from."
::= { itmex2atvSystem 23 }
itmex2atvSystemInstrumentKU OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument serial number."
::= { itmex2atvSystem 1 }
itmex2atvSystemInstrumentType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product type designation."
::= { itmex2atvSystem 2 }
itmex2atvSystemInstrumentOptions OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The options installed on this instrument."
::= { itmex2atvSystem 6 }
itmex2atvSystemDateTimeSync OBJECT-TYPE
SYNTAX INTEGER { manual(0), auto(1), gps(2), ntp(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The method used to synchronize system RTC. Mode auto means use
gps if available else ntp else manual."
::= { itmex2atvSystem 20 }
itmex2atvSystemDateTimeSyncActual OBJECT-TYPE
SYNTAX INTEGER { manual(0), auto(1), gps(2), ntp(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The actual method used to synchronize system RTC."
::= { itmex2atvSystem 31 }
itmex2atvSystemTimezone OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Time Zone used for displaying Data and Time."
::= { itmex2atvSystem 21 }
itmex2atvSystemInstrumentSWRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Software Revision currently running."
::= { itmex2atvSystem 3 }
itmex2atvSystemInstrumentBootLoaderRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument Bootloader Software Revision."
::= { itmex2atvSystem 4 }
itmex2atvSystemInstrumentKernelRev OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The instrument O/S Kernel Version."
::= { itmex2atvSystem 5 }
itmex2atvSystemOperationOnTime OBJECT-TYPE
SYNTAX Integer32
UNITS "1 secs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds this unit has been turned on since production."
::= { itmex2atvSystem 34 }
itmex2atvSystemOperationOnAirTime OBJECT-TYPE
SYNTAX Integer32
UNITS "1 secs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds this unit has been unmuted since production."
::= { itmex2atvSystem 35 }
itmex2atvSystemOperationNumberOfBoots OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of times this unit has been booted since last factory
default restore."
::= { itmex2atvSystem 36 }
itmex2atvSystemBackplaneid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ID of the backplane the device is plugged into"
::= { itmex2atvSystem 40 }
itmex2atvSystemBackplaneIdRaw OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Raw ID of the backplane the device is plugged into"
::= { itmex2atvSystem 41 }
itmex2atvSystemBackplaneIdPcb OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCB version of the backplane the device is plugged into"
::= { itmex2atvSystem 42 }
itmex2atvSystemBackplaneIdCableOptions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cable options of the backplane the device is plugged into"
::= { itmex2atvSystem 43 }
itmex2atvSystemBackplaneIdMAnuf OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Manufacture ID of the backplane the device is plugged into"
::= { itmex2atvSystem 44 }
itmex2atvSystemBackplaneCalibrationDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration date of the backplane the device is plugged into"
::= { itmex2atvSystem 45 }
itmex2atvSystemBackplaneCalibrationSw OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration SW version of the backplane the device is plugged
into"
::= { itmex2atvSystem 46 }
itmex2atvSystemBackplaneIdPartlist OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Partlist version of the backplane the device is plugged into"
::= { itmex2atvSystem 47 }
-- Scheduled Action table --
itmex2atvSystemScheduledActionTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvSystemScheduledActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the scheduled actions"
::= { itmex2atvSystem 50 }
itmex2atvSystemScheduledActionEntry OBJECT-TYPE
SYNTAX Itmex2atvSystemScheduledActionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the scheduled action"
INDEX { itmex2atvSystemScheduledActionID }
::= { itmex2atvSystemScheduledActionTable 1 }
Itmex2atvSystemScheduledActionEntry ::= SEQUENCE {
itmex2atvSystemScheduledActionID Integer32,
itmex2atvSystemScheduledActionRecurrence INTEGER,
itmex2atvSystemScheduledActionHour Integer32,
itmex2atvSystemScheduledActionMinute Integer32,
itmex2atvSystemScheduledActionWeekday INTEGER,
itmex2atvSystemScheduledActionMonthDay Integer32,
itmex2atvSystemScheduledActionDate DisplayString,
itmex2atvSystemScheduledActionRandomDelay Integer32,
itmex2atvSystemScheduledActionAction INTEGER,
itmex2atvSystemScheduledActionRepeaterMode INTEGER,
itmex2atvSystemScheduledActionPresetNo INTEGER,
itmex2atvSystemScheduledActionRebootImage INTEGER,
itmex2atvSystemScheduledActionRebootSystemType INTEGER,
itmex2atvSystemScheduledActionMute INTEGER,
itmex2atvSystemScheduledActionSWUpgradeProtocol INTEGER,
itmex2atvSystemScheduledActionSWUpgradeUsername DisplayString,
itmex2atvSystemScheduledActionSWUpgradePassword DisplayString,
itmex2atvSystemScheduledActionSWUpgradeImageServer DisplayString,
itmex2atvSystemScheduledActionSWUpgradeImagePath DisplayString
}
itmex2atvSystemScheduledActionID OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 10 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this scheduled action entry"
::= { itmex2atvSystemScheduledActionEntry 1 }
itmex2atvSystemScheduledActionRecurrence OBJECT-TYPE
SYNTAX INTEGER { never(0), immediate(1), once(2), hourly(3), daily(4), weekly(5), monthly(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval at which this scheduled action entry will be executed"
::= { itmex2atvSystemScheduledActionEntry 2 }
itmex2atvSystemScheduledActionHour OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 23 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence hour used when itmex2atvSystemScheduledActionRecurrence is once, hourly, dayly, weekly and monthly."
::= { itmex2atvSystemScheduledActionEntry 3 }
itmex2atvSystemScheduledActionMinute OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 59 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence minute used when itmex2atvSystemScheduledActionRecurrence is once, hourly, dayly, weekly and monthly."
::= { itmex2atvSystemScheduledActionEntry 4 }
itmex2atvSystemScheduledActionWeekday OBJECT-TYPE
SYNTAX INTEGER { monday(0), tuesday(1), wednesday(2), thursday(3), friday(4), saturday(5), sunday(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence weekday used when itmex2atvSystemScheduledActionRecurrence is weekly."
::= { itmex2atvSystemScheduledActionEntry 5 }
itmex2atvSystemScheduledActionMonthDay OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 31 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence day of the monthe used when itmex2atvSystemScheduledActionRecurrence is monthly."
::= { itmex2atvSystemScheduledActionEntry 6 }
itmex2atvSystemScheduledActionDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The recurrence date used when itmex2atvSystemScheduledActionRecurrence is once.
The format is dd/mm/yyyy."
::= { itmex2atvSystemScheduledActionEntry 7 }
itmex2atvSystemScheduledActionRandomDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 600 )
UNITS "secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An extra random delay added before the action for this entry is executed.
A setting of x means that a random delay between 0 and x seconds are added."
::= { itmex2atvSystemScheduledActionEntry 8 }
itmex2atvSystemScheduledActionAction OBJECT-TYPE
SYNTAX INTEGER { none(0), repeatermode(1), preset(2), swupgrade(3), reboot(4), mute(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The action for this entry is executed"
::= { itmex2atvSystemScheduledActionEntry 9 }
itmex2atvSystemScheduledActionRepeaterMode OBJECT-TYPE
SYNTAX INTEGER { auto(0),
digital-iso-repeater(1),
digital-transposer(2),
analog-iso-repeater(3),
analog-transposer(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The new repeater mode to change to when itmex2atvSystemScheduledActionAction
of type repeatermode is executed"
::= { itmex2atvSystemScheduledActionEntry 10 }
itmex2atvSystemScheduledActionPresetNo OBJECT-TYPE
SYNTAX INTEGER { auto(0),
digital-iso-repeater(1),
digital-transposer(2),
analog-iso-repeater(3),
analog-transposer(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The preset to load when itmex2atvSystemScheduledActionAction
of type preset is executed"
::= { itmex2atvSystemScheduledActionEntry 11 }
itmex2atvSystemScheduledActionRebootImage OBJECT-TYPE
SYNTAX INTEGER { sameimage(0), otherimage(1), image0(2), image1(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The image to reboot to when itmex2atvSystemScheduledActionAction
of type reboot is executed"
::= { itmex2atvSystemScheduledActionEntry 12 }
itmex2atvSystemScheduledActionRebootSystemType OBJECT-TYPE
SYNTAX INTEGER { modulator(0), repeater(1), same(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The system type to reboot to when itmex2atvSystemScheduledActionAction
of type reboot is executed"
::= { itmex2atvSystemScheduledActionEntry 13 }
itmex2atvSystemScheduledActionMute OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The mute mode to change into when itmex2atvSystemScheduledActionAction
of type mute is executed"
::= { itmex2atvSystemScheduledActionEntry 14 }
itmex2atvSystemScheduledActionSWUpgradeProtocol OBJECT-TYPE
SYNTAX INTEGER { http(0), ftp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The protocol to use into when itmex2atvSystemScheduledActionAction
of type swupgrade(3) is executed"
::= { itmex2atvSystemScheduledActionEntry 15 }
itmex2atvSystemScheduledActionSWUpgradeUsername OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The username to use into when itmex2atvSystemScheduledActionAction
of type swupgrade(3) is executed"
::= { itmex2atvSystemScheduledActionEntry 16 }
itmex2atvSystemScheduledActionSWUpgradePassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password to use into when itmex2atvSystemScheduledActionAction
of type swupgrade(3) is executed"
::= { itmex2atvSystemScheduledActionEntry 17 }
itmex2atvSystemScheduledActionSWUpgradeImageServer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The server name to use into when itmex2atvSystemScheduledActionAction
of type swupgrade(3) is executed"
::= { itmex2atvSystemScheduledActionEntry 18 }
itmex2atvSystemScheduledActionSWUpgradeImagePath OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The image path name to use into when itmex2atvSystemScheduledActionAction
of type swupgrade(3) is executed"
::= { itmex2atvSystemScheduledActionEntry 19 }
--
-- itmex2atv Mode sub-tree
--
--
-- itmex2atv ATV sub-tree
--
itmex2atvAtvModeStandardVideo OBJECT-TYPE
SYNTAX INTEGER { bg(0), d1(1), m(2), dk(3), i1(4), k1(5), n(6), nc(7), i(8) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select analogue TV Video Standard"
::= { itmex2atvAtv 1 }
itmex2atvAtvModeStandardColor OBJECT-TYPE
SYNTAX INTEGER { pal(0), ntsc(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select color encoding system"
::= { itmex2atvAtv 12 }
itmex2atvAtvModeStandardAudioCtrl OBJECT-TYPE
SYNTAX INTEGER { off(0), mono(1), stereo(2), dual(3), mpx(4), teletext(5), nicam(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select analogue TV Audio Standard"
::= { itmex2atvAtv 2 }
itmex2atvAtvModeStandardAudioStatus OBJECT-TYPE
SYNTAX INTEGER { off(0), mono(1), stereo(2), dual(3), mpx(4), teletext(5), nicam(6), fault(7), na(8) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of selected analogue TV Audio Standard"
::= { itmex2atvAtv 3 }
itmex2atvAtvModeStandardAudioEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of correct audio encoder selection 0 = OK"
::= { itmex2atvAtv 4 }
itmex2atvAtvModeStandardAudioImpendance OBJECT-TYPE
SYNTAX INTEGER { high(0), matched(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Audio input source impedance"
::= { itmex2atvAtv 13 }
itmex2atvAtvModeStandardAudioMpx OBJECT-TYPE
SYNTAX INTEGER { balanced(0), unbalanced(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Audio input source impedance"
::= { itmex2atvAtv 14 }
itmex2atvAtvModeTeletextline OBJECT-TYPE
SYNTAX Integer32 ( 6 .. 335 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Start Line of Teletext"
::= { itmex2atvAtv 5 }
itmex2atvAtvModeTeletextThreshold OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 625 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Alarm Threshold Line of Teletext"
::= { itmex2atvAtv 6 }
itmex2atvAtvModeTeletextEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of teletext is within threshold limit 0 = OK"
::= { itmex2atvAtv 7 }
itmex2atvAtvModecarrierSound1 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sound Carrier Control"
::= { itmex2atvAtv 8 }
itmex2atvAtvModecarrierSound2 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sound Carrier Control"
::= { itmex2atvAtv 9 }
itmex2atvAtvModecarrierSub OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sub Carrier Control"
::= { itmex2atvAtv 10 }
itmex2atvAtvModecarrierVideo OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Video Carrier Control"
::= { itmex2atvAtv 11 }
itmex2atvAtvvideoStatus OBJECT-TYPE
SYNTAX INTEGER { normal(0), low(1), overload(2), absent(3), whitelim(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of selected Video"
::= { itmex2atvAtv 100 }
itmex2atvAtvvideoitsline OBJECT-TYPE
SYNTAX Integer32 ( 6 .. 335 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select position of ITS Line"
::= { itmex2atvAtv 101 }
itmex2atvAtvvideoWhitelimit OBJECT-TYPE
SYNTAX Integer32 ( 85 .. 95 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select White limit in percent"
::= { itmex2atvAtv 102 }
itmex2atvAtvvideoSynclevel OBJECT-TYPE
SYNTAX Integer32 ( 20 .. 30 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Sync level in percent"
::= { itmex2atvAtv 103 }
itmex2atvAtvvideoResidualCarrier OBJECT-TYPE
SYNTAX Integer32 ( 5 .. 20 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select residual carrier in percent"
::= { itmex2atvAtv 104 }
itmex2atvAtvvideoAgc OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Video Carrier Control"
::= { itmex2atvAtv 105 }
itmex2atvAtvvideon1ManualGain OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 590 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set manual gain"
::= { itmex2atvAtv 106 }
itmex2atvAtvvideon2ManualGain OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 590 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set manual gain"
::= { itmex2atvAtv 107 }
itmex2atvAtvvideoGroupDelay OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set group delay filter on /off"
::= { itmex2atvAtv 108 }
itmex2atvAtvvideoeventLevellow OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of video level Low 0 = OK"
::= { itmex2atvAtv 120 }
itmex2atvAtvvideoeventLevelhigh OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of video level High 0 = OK"
::= { itmex2atvAtv 121 }
itmex2atvAtvvideoeventOverload OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of Video Overload 0 = OK"
::= { itmex2atvAtv 122 }
itmex2atvAtvvideoeventWhitelimit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of White Limit 0 = OK"
::= { itmex2atvAtv 123 }
itmex2atvAtvvideoeventitsline OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of ITS Line 0 = OK"
::= { itmex2atvAtv 124 }
itmex2atvAtvvideoeventn1Present OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of Video 1 Present 0 = OK"
::= { itmex2atvAtv 125 }
itmex2atvAtvvideoeventn2Present OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of Video 2 Present 0 = OK"
::= { itmex2atvAtv 126 }
itmex2atvAtvvideoSilenceDetector OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 3600 )
UNITS "1 s"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set number of seconds that ON-AIR video signal shall be missing
before mute (use 'emit blanking' OFF)"
::= { itmex2atvAtv 127 }
itmex2atvAtvvideoSilenceEmitBlanking OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If ON, The Moduklator will keep emiting blanking level else
if OFF the mechanism Trigger Mute on silence detector"
::= { itmex2atvAtv 128 }
itmex2atvAtvAudioN1Status OBJECT-TYPE
SYNTAX INTEGER { normal(0), overdrive(1), overflow(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of Audio input 1"
::= { itmex2atvAtv 200 }
itmex2atvAtvAudioN2Status OBJECT-TYPE
SYNTAX INTEGER { normal(0), overdrive(1), overflow(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of Audio input 2"
::= { itmex2atvAtv 201 }
itmex2atvAtvAudioSubcarrierStatus OBJECT-TYPE
SYNTAX INTEGER { normal(0), overdrive(1), overflow(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of Sub Carrier input"
::= { itmex2atvAtv 202 }
itmex2atvAtvAudioCarrierLevelAudio1 OBJECT-TYPE
SYNTAX Integer32 ( -2700 .. -419 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Level for Aduio 1"
::= { itmex2atvAtv 203 }
itmex2atvAtvAudioCarrierLevelAudio2 OBJECT-TYPE
SYNTAX Integer32 ( -2700 .. -419 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Level for Aduio 2"
::= { itmex2atvAtv 204 }
itmex2atvAtvAudioGainAudio1 OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Gain for Aduio 1"
::= { itmex2atvAtv 205 }
itmex2atvAtvAudioGainAudio2 OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Gain for Aduio 2"
::= { itmex2atvAtv 206 }
itmex2atvAtvAudioGainPilot OBJECT-TYPE
SYNTAX Integer32 ( -2100 .. 290 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Gain for Pilot"
::= { itmex2atvAtv 207 }
itmex2atvAtvAudiolimiterAudio1 OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10000 )
UNITS "0.01 kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set Limits for Audio 1 deviation"
::= { itmex2atvAtv 208 }
itmex2atvAtvAudiolimiterAudio2 OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10000 )
UNITS "0.01 kHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set Limits for Audio 2 deviation"
::= { itmex2atvAtv 209 }
itmex2atvAtvAudiopreemphasisn1 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Preemphasis1 Control"
::= { itmex2atvAtv 211 }
itmex2atvAtvAudiopreemphasisn2 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Preemphasis2 Control"
::= { itmex2atvAtv 212 }
itmex2atvAtvAudiooverdriveAudio1Event OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of signal overdrive 0 = OK"
::= { itmex2atvAtv 220 }
itmex2atvAtvAudiooverdriveAudio2Event OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of signal overdrive 0 = OK"
::= { itmex2atvAtv 221 }
itmex2atvAtvAudiooverdriveSubCarrierEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of signal overdrive 0 = OK"
::= { itmex2atvAtv 222 }
itmex2atvAtvAudiooverflowAudio1Event OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of signal overflow 0 = OK"
::= { itmex2atvAtv 223 }
itmex2atvAtvAudiooverflowAudio2Event OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of signal overflow 0 = OK"
::= { itmex2atvAtv 224 }
itmex2atvAtvAudiooverflowSubCarrierEvent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicator of signal overflow 0 = OK"
::= { itmex2atvAtv 225 }
itmex2atvAtvAudioInputlevelLeft OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBu"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"level"
::= { itmex2atvAtv 226 }
itmex2atvAtvAudioInputlevelRight OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBu"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"level"
::= { itmex2atvAtv 227 }
itmex2atvAtvAudioInputlevelNicam OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBu"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"level"
::= { itmex2atvAtv 228 }
itmex2atvAtvAudioInputlevelSub OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBu"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"level"
::= { itmex2atvAtv 229 }
itmex2atvAtvAudioInputlevelMpx OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBu"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"level"
::= { itmex2atvAtv 230 }
itmex2atvAtvAudioInputStatusLeft OBJECT-TYPE
SYNTAX INTEGER { ok(0), fail(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { itmex2atvAtv 231 }
itmex2atvAtvAudioInputStatusRight OBJECT-TYPE
SYNTAX INTEGER { ok(0), fail(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { itmex2atvAtv 232 }
itmex2atvAtvAudioInputStatusNicam OBJECT-TYPE
SYNTAX INTEGER { ok(0), fail(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { itmex2atvAtv 233 }
itmex2atvAtvAudioInputStatusSub OBJECT-TYPE
SYNTAX INTEGER { ok(0), fail(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { itmex2atvAtv 234 }
itmex2atvAtvAudioInputStatusMpx OBJECT-TYPE
SYNTAX INTEGER { ok(0), fail(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status"
::= { itmex2atvAtv 235 }
itmex2atvAtvAudioInputSilenceDetector OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 3600 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set number of seconds that signal shall be below threshold"
::= { itmex2atvAtv 236 }
itmex2atvAtvAudioInputSilenceThreshold OBJECT-TYPE
SYNTAX Integer32 ( -5000 .. 0 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Threshold for silence detector"
::= { itmex2atvAtv 237 }
itmex2atvAtvNicamStatus OBJECT-TYPE
SYNTAX INTEGER { normal(0), fault(1), noextdata(2), warning(3), na(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of selected Nicam coder"
::= { itmex2atvAtv 300 }
itmex2atvAtvNicamCoder OBJECT-TYPE
SYNTAX INTEGER { stereo(0), dual(1), monodata(2), external(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NICAM Coder Control"
::= { itmex2atvAtv 302 }
itmex2atvAtvNicamBackup OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"NICAM Coder Control. If monosource is set to SUM nicam.backup
is forced to YES (Internaly ... not on UI)"
::= { itmex2atvAtv 303 }
itmex2atvAtvNicamGainn1 OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Nicam n1 Gain setting"
::= { itmex2atvAtv 304 }
itmex2atvAtvNicamGainn2 OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Nicam n2 Gain setting"
::= { itmex2atvAtv 305 }
itmex2atvAtvNicampreemphasisn1 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Preemphasis1 Control"
::= { itmex2atvAtv 306 }
itmex2atvAtvNicampreemphasisn2 OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Preemphasis2 Control"
::= { itmex2atvAtv 307 }
itmex2atvAtvNicamadditionalData OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Additional Nicam data"
::= { itmex2atvAtv 308 }
itmex2atvAtvNicammonosource OBJECT-TYPE
SYNTAX INTEGER { sep(0), sum(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select Nicam mono source. If monosource is set to SUM nicam.backup
is forced to YES (Internaly ... not on UI)"
::= { itmex2atvAtv 309 }
itmex2atvAtvHardwarePcbRevision OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCB version of the ATV board in the expansion connector."
::= { itmex2atvAtv 10050 }
itmex2atvAtvHardwareBomRevision OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"BOM version of the ATV board in the expansion connector."
::= { itmex2atvAtv 10051 }
itmex2atvAtvInputSwPending OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Waiting for switch input"
::= { itmex2atvAtv 10100 }
itmex2atvAtvInputSwSelected OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Input INPA/INPB (0/1) selected"
::= { itmex2atvAtv 10101 }
itmex2atvAtvInputStateinpa OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"inpa state"
::= { itmex2atvAtv 10102 }
itmex2atvAtvInputStateinpb OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"inpb state"
::= { itmex2atvAtv 10103 }
itmex2atvAtvInputStatesdi1 OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sdi0 state"
::= { itmex2atvAtv 10104 }
itmex2atvAtvInputStatesdi2 OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"sdi1 state"
::= { itmex2atvAtv 10105 }
itmex2atvAtvInputStateanl1 OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Analog 1 state"
::= { itmex2atvAtv 10106 }
itmex2atvAtvInputStateanl2 OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Analog 2 state"
::= { itmex2atvAtv 10107 }
--
-- itmex2atv Input sub-tree
--
itmex2atvInputRefOcxoDevType OBJECT-TYPE
SYNTAX INTEGER { tcxo-int(0), ocxo-pt3710-10(1), ocxo-pt3710-20(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Type of TCXO/OCXO"
::= { itmex2atvInput 90 }
itmex2atvInputRefOcxoCalDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration Date"
::= { itmex2atvInput 91 }
itmex2atvInputRefOcxoCalVer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Calibration SW Version"
::= { itmex2atvInput 92 }
itmex2atvInputRefDirection OBJECT-TYPE
SYNTAX INTEGER { input(0), output(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"monitors the Reference signal direction. state: - inputOutput[inputOutput_INPUT]
- inputOutput[inputOutput_OUTPUT]"
::= { itmex2atvInput 1 }
itmex2atvInputRefSource OBJECT-TYPE
SYNTAX INTEGER { auto(0), ext(1), int(2), gps(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the input reference synchronisation source. If the value
AUTO is chosen, the source is chosen automatically between
available sources. The order of choice is GPS->EXT10MHz->INT.
If the value EXT is chosen, the external clock is chosen as
source If the value INT is chosen, the internal clock is chosen
as source. If the value GPS is chosen, the GNSS 1PPS clock
is chosen as source."
::= { itmex2atvInput 2 }
itmex2atvInputRefStatus OBJECT-TYPE
SYNTAX INTEGER { external(0), external-10mhz(1), external-1pps(2), internal(3), gnss(4), asi1(5), asi2(6), ndel(7) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"returns the current input reference synchronisation source."
::= { itmex2atvInput 11 }
itmex2atvInputRef10MhzImpedance OBJECT-TYPE
SYNTAX INTEGER { o-50(0), himp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 10 MHz input reference synchronisation
source impedance. The value is either 50O or high impedance."
::= { itmex2atvInput 3 }
itmex2atvInputRef10MhzHoldoverDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 172800 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 10 MHz input reference synchronisation
source impedance. The value is either 50O or high impedance."
::= { itmex2atvInput 7 }
itmex2atvInputRef10MhzHoldoverForever OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holdover delay for input reference source 10MHz failure
is forever"
::= { itmex2atvInput 8 }
itmex2atvInputRef1PPSImpedance OBJECT-TYPE
SYNTAX INTEGER { o-50(0), himp(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 1 PPS input reference synchronisation source
impedance. The value is either 50ohm or high impedance."
::= { itmex2atvInput 4 }
itmex2atvInputRef1PPSHoldoverDelay OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 172800 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the external 1 PPS input reference synchronisation source
impedance. The value is either 50ohm or high impedance."
::= { itmex2atvInput 9 }
itmex2atvInputRef1PPSHoldoverForever OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holdover delay for input reference source 1 pps failure
is forever"
::= { itmex2atvInput 10 }
itmex2atvInputRef1PPSTrigSlope OBJECT-TYPE
SYNTAX INTEGER { rising(0), falling(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the trigger edge of the external 1PPS input reference
clock. The value is either RISING or FALLING."
::= { itmex2atvInput 5 }
itmex2atvInputRef1PPSTrigLevel OBJECT-TYPE
SYNTAX Integer32 ( 10 .. 16 )
UNITS "0.1 v"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the trigger level of the external 1PPS input reference
clock"
::= { itmex2atvInput 6 }
itmex2atvInputASIAutoRoutingDelayHp2Lp OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 300 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay before performing the actual substitution where TS-Primary
-> TS-LP and TS-Secondary -> TS-HP"
::= { itmex2atvInput 15 }
itmex2atvInputASIAutoRoutingDelayLp2Hp OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 300 )
UNITS "1 secs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The delay before performing the actual substitution where TS-Primary
-> TS-HP and TS-Secondary -> TS-LP"
::= { itmex2atvInput 16 }
itmex2atvInputASITSPrimarySource OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
satRecv(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TS-Primary input source connector selected"
::= { itmex2atvInput 12 }
itmex2atvInputASITSSecondarySource OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
satRecv(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TS-Secondary input source connector selected"
::= { itmex2atvInput 13 }
itmex2atvInputASIAutoRoutingPolicy OBJECT-TYPE
SYNTAX INTEGER { only-use-primary(0), only-use-secondary(1),
use-primary-if-available(2), use-any-available(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The policy to use for TS auto routing"
::= { itmex2atvInput 14 }
itmex2atvInputTSPrimaryStatus OBJECT-TYPE
SYNTAX INTEGER { available(0), unavailable(1), nosync(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state for TS-Primary. Unavailable means violation of alarms."
::= { itmex2atvInput 36 }
itmex2atvInputTSSecondaryStatus OBJECT-TYPE
SYNTAX INTEGER { available(0), unavailable(1), nosync(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state for TS-Secondary. Unavailable means violation of alarms."
::= { itmex2atvInput 37 }
itmex2atvInputTSHp OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
satRecv(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input source currently On Air. (TS-HP)"
::= { itmex2atvInput 38 }
itmex2atvInputTSLp OBJECT-TYPE
SYNTAX INTEGER {
asi-in-1(0), asi-in-2(1),
satRecv(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The input source currently used as backup. (TS-LP)"
::= { itmex2atvInput 39 }
itmex2atvInputEffectiveAutoroutingPolicy OBJECT-TYPE
SYNTAX INTEGER { only-primary(0), only-secondary(1), prefer-primary(2), any-available(3), seamless(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reflects the effective Autorouting Policy"
::= { itmex2atvInput 40 }
itmex2atvInputTSHpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "Kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current bitrate for On Air TS. (TS-HP)"
::= { itmex2atvInput 41 }
itmex2atvInputTSLpBitrate OBJECT-TYPE
SYNTAX Integer32
UNITS "Kb/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current bitrate for Backup TS. (TS-LP)"
::= { itmex2atvInput 47 }
--
-- itmex2atv Output sub-tree
--
itmex2atvOutputBandwidth OBJECT-TYPE
SYNTAX Integer32 ( 60 .. 80 )
UNITS "0.1 MHz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output Bandwidth"
::= { itmex2atvOutput 4 }
itmex2atvOutputChannel OBJECT-TYPE
SYNTAX Integer32 ( 21 .. 69 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Channel settings"
::= { itmex2atvOutput 5 }
itmex2atvOutputSynchronized OBJECT-TYPE
SYNTAX INTEGER { not-synchronized(0), synchronized(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The values of itmex2atvOutputRfFrequency, itmex2atvOutputBandwidth and
itmex2atvOutputChannel are synchronized aaccording to
freq = (bw * channel) + 306000000."
::= { itmex2atvOutput 6 }
itmex2atvOutputPowerLevel OBJECT-TYPE
SYNTAX Integer32 ( 280 .. 490 )
UNITS "0.1 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired output power level."
::= { itmex2atvOutput 9 }
itmex2atvOutputMode OBJECT-TYPE
SYNTAX INTEGER { normal(0), standby(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control RF output mode"
::= { itmex2atvOutput 1 }
itmex2atvOutputEffectiveLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Effective RF Output Level"
::= { itmex2atvOutput 17 }
itmex2atvOutputActualLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Actual RF Output Level"
::= { itmex2atvOutput 18 }
itmex2atvOutputPolarity OBJECT-TYPE
SYNTAX INTEGER { norm(0), inv(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control output polarity"
::= { itmex2atvOutput 8 }
itmex2atvOutputRfFrequency OBJECT-TYPE
SYNTAX Integer32 ( 30000000 .. 860000000 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output RF frequency"
::= { itmex2atvOutput 2 }
itmex2atvOutputRfFrequencyOffset OBJECT-TYPE
SYNTAX Integer32 ( -8388608 .. 8388607 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Output RF frequency offset"
::= { itmex2atvOutput 10 }
itmex2atvOutputRfLevel OBJECT-TYPE
SYNTAX Integer32 ( -700 .. 1300 )
UNITS "0.01 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the output sync level in 0.01dB steps"
::= { itmex2atvOutput 3 }
itmex2atvOutputRfCableMode OBJECT-TYPE
SYNTAX INTEGER { none(0), const(1), auto(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control whether Cable Level loss compensation should be enabled"
::= { itmex2atvOutput 50 }
itmex2atvOutputRfCableConstantLevelOffset OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Constant level offset to add to RF Output level. Only used if
mode is Constant."
::= { itmex2atvOutput 51 }
itmex2atvOutputRfCableFrequencyLevelOffset0 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { itmex2atvOutput 52 }
itmex2atvOutputRfCableFrequencyLevelOffset1 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { itmex2atvOutput 53 }
itmex2atvOutputRfCableFrequencyLevelOffset2 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { itmex2atvOutput 54 }
itmex2atvOutputRfCableFrequencyLevelOffset3 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { itmex2atvOutput 55 }
itmex2atvOutputRfCableFrequencyLevelOffset4 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { itmex2atvOutput 56 }
itmex2atvOutputRfCableFrequencyLevelOffset5 OBJECT-TYPE
SYNTAX Integer32 ( -10000 .. 10000 )
UNITS "0.001 dBm"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frequency depedent level offset to add to RF Output level. Only
used if mode is Automatic."
::= { itmex2atvOutput 57 }
itmex2atvOutputRfDetectedActualLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.01 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Detected Output Level for RF"
::= { itmex2atvOutput 19 }
itmex2atvOutputRfDetectedLowerLevelLimit OBJECT-TYPE
SYNTAX Integer32 ( 60 .. 100 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Limit to how much lower the detected RF output level can be
than the configured level."
::= { itmex2atvOutput 20 }
itmex2atvOutputRfDetectedLowerLevelcontrol OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the lower limit for RF output level is enforced."
::= { itmex2atvOutput 21 }
itmex2atvOutputRfDetectedHigherLevelLimit OBJECT-TYPE
SYNTAX Integer32 ( 2 .. 50 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Limit to how much higher the detected RF output level can be
than the configured level."
::= { itmex2atvOutput 22 }
itmex2atvOutputRfDetectedHigherLevelcontrol OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the higher limit for RF output level is enforced."
::= { itmex2atvOutput 23 }
itmex2atvOutputRfAlcControl OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the ALC system is enabled or disabled."
::= { itmex2atvOutput 30 }
itmex2atvOutputRfAlcSense OBJECT-TYPE
SYNTAX INTEGER { rfsense1(0), rfsense2(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls which sense port is used by the ALC system if the ALC
is enabled."
::= { itmex2atvOutput 31 }
itmex2atvOutputRfAlcSetpointPort1 OBJECT-TYPE
SYNTAX Integer32 ( -11000 .. 11000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ALC setpoint for RF Sense Port 1"
::= { itmex2atvOutput 32 }
itmex2atvOutputRfAlcSetpointPort2 OBJECT-TYPE
SYNTAX Integer32 ( -11000 .. 11000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ALC setpoint for RF Sense Port 2"
::= { itmex2atvOutput 33 }
itmex2atvOutputRfAlcMarkSetpoint1 OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mark the current RF output level as setpoint for RF Sense Port1."
::= { itmex2atvOutput 36 }
itmex2atvOutputRfAlcMarkSetpoint2 OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Mark the current RF output level as setpoint for RF Sense Port2."
::= { itmex2atvOutput 37 }
itmex2atvOutputRfAlcStatus OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status for whether the ALC system is enabled or disabled."
::= { itmex2atvOutput 34 }
itmex2atvOutputRfAlcStatusInformation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the state of the ALC system."
::= { itmex2atvOutput 35 }
itmex2atvOutputMute OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control Output Rf Mute User request. Output mute. When set the
mute reason UserRequest is ORed into the mute reason set. When
read it is the logical OR of all mute reasons"
::= { itmex2atvOutput 7 }
itmex2atvOutputMuteReason OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Mute reason."
::= { itmex2atvOutput 58 }
itmex2atvOutputHpaStatus1Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1000 }
itmex2atvOutputHpaStatus2Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1002 }
itmex2atvOutputHpaStatus3Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1004 }
itmex2atvOutputHpaStatus4Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1006 }
itmex2atvOutputHpaStatus5Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1008 }
itmex2atvOutputHpaStatus6Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1010 }
itmex2atvOutputHpaStatus7Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1012 }
itmex2atvOutputHpaStatus8Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1014 }
itmex2atvOutputHpaStatus9Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1016 }
itmex2atvOutputHpaStatus10Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1018 }
itmex2atvOutputHpaStatus11Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1020 }
itmex2atvOutputHpaStatus12Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1022 }
itmex2atvOutputHpaStatus1Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1001 }
itmex2atvOutputHpaStatus2Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1003 }
itmex2atvOutputHpaStatus3Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1005 }
itmex2atvOutputHpaStatus4Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1007 }
itmex2atvOutputHpaStatus5Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1009 }
itmex2atvOutputHpaStatus6Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1011 }
itmex2atvOutputHpaStatus7Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1013 }
itmex2atvOutputHpaStatus8Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1015 }
itmex2atvOutputHpaStatus9Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1017 }
itmex2atvOutputHpaStatus10Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1019 }
itmex2atvOutputHpaStatus11Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1021 }
itmex2atvOutputHpaStatus12Param OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the param field."
::= { itmex2atvOutput 1023 }
itmex2atvOutputHpaAlarm1Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1030 }
itmex2atvOutputHpaAlarm2Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1032 }
itmex2atvOutputHpaAlarm3Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1034 }
itmex2atvOutputHpaAlarm4Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1036 }
itmex2atvOutputHpaAlarm5Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1038 }
itmex2atvOutputHpaAlarm6Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1040 }
itmex2atvOutputHpaAlarm7Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1042 }
itmex2atvOutputHpaAlarm8Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1044 }
itmex2atvOutputHpaAlarm9Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1046 }
itmex2atvOutputHpaAlarm10Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1048 }
itmex2atvOutputHpaAlarm11Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1050 }
itmex2atvOutputHpaAlarm12Text OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Information on the text field."
::= { itmex2atvOutput 1052 }
itmex2atvOutputHpaAlarm1Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1031 }
itmex2atvOutputHpaAlarm2Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1033 }
itmex2atvOutputHpaAlarm3Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1035 }
itmex2atvOutputHpaAlarm4Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1037 }
itmex2atvOutputHpaAlarm5Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1039 }
itmex2atvOutputHpaAlarm6Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1041 }
itmex2atvOutputHpaAlarm7Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1043 }
itmex2atvOutputHpaAlarm8Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1045 }
itmex2atvOutputHpaAlarm9Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1047 }
itmex2atvOutputHpaAlarm10Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1049 }
itmex2atvOutputHpaAlarm11Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1051 }
itmex2atvOutputHpaAlarm12Status OBJECT-TYPE
SYNTAX INTEGER { ok(0), alarm(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA Alarm Status OK-0 ALARM-1"
::= { itmex2atvOutput 1053 }
itmex2atvOutputHpaPowerForward OBJECT-TYPE
SYNTAX Integer32
UNITS "1 Watt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA forward power."
::= { itmex2atvOutput 1100 }
itmex2atvOutputHpaPowerReflected OBJECT-TYPE
SYNTAX Integer32
UNITS "1 Watt"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA reflected power"
::= { itmex2atvOutput 1101 }
itmex2atvOutputHpaPowerHeatsinkTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "1 C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HPA heat sink temperatur in celcius"
::= { itmex2atvOutput 1102 }
--
-- itmex2atv GPS sub-tree
--
itmex2atvGpsInUse OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Defines wheter to use gps. Depends on Options in effect"
::= { itmex2atvGps 20 }
itmex2atvGpsMaintenance OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"GNSS in maintenance mode. i.e. upgrade firmware. !!!DO NOT POWER
OFF, when in this mode you may brick the GNSS module!!!"
::= { itmex2atvGps 100 }
itmex2atvGpsBias OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the bias to be either on or off for the GPS antenna
DC supply (5V or 3V DC). An active GPS antenna requires a power
supply i.e. requires this parameter to set to ON."
::= { itmex2atvGps 4 }
itmex2atvGpsbiasVoltage OBJECT-TYPE
SYNTAX INTEGER { gpsant-5v(0), gpsant-33v(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the gps antenna bias voltage. An active GPS antenna
requires a power supply of either 3V or 5V."
::= { itmex2atvGps 15 }
itmex2atvGpsCableDelay OBJECT-TYPE
SYNTAX Integer32 ( -3000 .. 3000 )
UNITS "0.1 ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the antenna cable compensation delay. If the GPS antenna
is situated far away from the receiver itself the signal will
be delayed and must be compensated."
::= { itmex2atvGps 12 }
itmex2atvGpsHoldoverForever OBJECT-TYPE
SYNTAX INTEGER { no(0), yes(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines whether the GPS system is allowed to operate infinitely
(YES) following loss of GPS locking using the internal GPS
chip oscillator or not (NO).In case NO is chosen the GPS holdover
time applies."
::= { itmex2atvGps 11 }
itmex2atvGpsHoldoverTime OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 172800 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the GPS holdover time. This value is ignored if the
holdover forever (see below) is set to YES If the GPS locking
is lost the system is allowed to continue operating for holdover
time seconds using the internal GPS chip oscillator. If - when
the holdover time interval expires - the GPS locking it still
lost, the GPS operation will be maintained using external timing
if present. If external timing is not present the GPS operation
will be maintained using the internal motherboard oscillator."
::= { itmex2atvGps 10 }
itmex2atvGpsSatelliteSystemGPS OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether GPS satellites are used to obtain position
and timing information."
::= { itmex2atvGps 16 }
itmex2atvGpsSatelliteSystemGLONASS OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether GLONASS satellites are used to obtain position
and timing information."
::= { itmex2atvGps 17 }
itmex2atvGpsSatelliteSystemGALILEO OBJECT-TYPE
SYNTAX INTEGER { disable(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether GALILEO satellites are used to obtain position
and timing information."
::= { itmex2atvGps 18 }
itmex2atvGpsSatelliteSystemCOMPASS OBJECT-TYPE
SYNTAX INTEGER { disable(0) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether COMPASS satellites are used to obtain position
and timing information."
::= { itmex2atvGps 19 }
itmex2atvGpsVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the GPS chip firmware version as a string."
::= { itmex2atvGps 9 }
itmex2atvGps1PPSStatus OBJECT-TYPE
SYNTAX INTEGER { locked(0), unlocked(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the current locking state of the GPS system. The value
LOCKED indicates that the GPS system is locked to a sufficient
number of satellites to perform well. UNLOCKED indicates that
it is not. For the GPS system to perform well at least 4 satellites
must be visible with a proper signal to noise ratio."
::= { itmex2atvGps 1 }
itmex2atvGpsTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current date and time derived from
the received GPS signal(s). The string format is DD/MM/YYYY
HH:MM:SS according to the following: - DD in [1..31] means
the day, - MM in [1..12] means the month, - YYYY in [0 .. 9999]
means the year, - HH in [0 .. 23] means the hour, - MM in [0
.. 59] means the minute, and - SS in [0 .. 59] means the second.
Time is in UTC time zone (i.e. GMT) which in turn means that
daylight saving time does not apply."
::= { itmex2atvGps 21 }
itmex2atvGpsState OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns a string describing the GPS state. For informational
purposes."
::= { itmex2atvGps 13 }
itmex2atvGpsVisibleSatellitesSnr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the average signal to noise ratio of all visible satellites
via the built-in GPS receiver"
::= { itmex2atvGps 14 }
itmex2atvGpsTrackedSatellitesSnr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBHz"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the average signal to noise ratio of all tracked satellites
via the built-in GPS receiver"
::= { itmex2atvGps 22 }
itmex2atvGpsVisibleSatellites OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the number of currently visible satellites via the built-in
GPS receiver. A satellite is visible if at all detectable by
the GPS system i.e. regardless of signal to noise ratio. Note
that the upper value N can change with the launch of new satellites.
For some time, however, the GPS system has had a total of 24
satellites."
::= { itmex2atvGps 2 }
itmex2atvGpsTrackedSatellites OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns the number of currently tracked satellites via the GPS
receiver."
::= { itmex2atvGps 3 }
itmex2atvGpsLongtitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current longtitude derived from
the received GPS signal(s). The string format is DDD MM SS C.
according to the following: - DD denotes degrees in the intervals
[0 .. 180]. MM and SS denote minutes/seconds in the interval
[0 .. 59]. C denotes E, W (East, West)."
::= { itmex2atvGps 6 }
itmex2atvGpsLatitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current latitude derived from the
received GPS signal(s). The string format is DD MM SS C. according
to the following: - DD denotes degrees in the intervals [0
.. 90]. MM and SS denote minutes/seconds in the interval [0
.. 59]. C denotes N, S (North, South)."
::= { itmex2atvGps 7 }
itmex2atvGpsAltitude OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Returns - as a string - the current altitude derived from the
received GPS signal(s). The string format is HHHH.c;. according
to the following: HHHH.c denotes the altitude in metres with
one digit after the comma. The altitude can be negative."
::= { itmex2atvGps 8 }
--
-- itmex2atv ChannelFilters sub-tree
--
--
-- itmex2atv Monitor sub-tree
--
--
-- itmex2atv Test sub-tree
--
itmex2atvTestEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), scar(1), black(2), bars(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"controls the test signal generation. This cannot be used when
network mode is SFN. Only a subset is available in repeater
mode. test signal output state: - testSignalsArray[testSignals_OFF]
Normal operation. No test signal. - testSignalsArray[testSignals_SCAR]
A single carrier output is provided."
::= { itmex2atvTest 1 }
itmex2atvTestEnableReconnect OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the test signal shall reconnect after reset.
This value is saved in non-volatile memory and thus survives
a reboot. - onOffArray[TEXT_INDEX_OFF] The selected test signal
will be set to OFF after reset. - onOffArray[TEXT_INDEX_ON]
The selected test signal will be output after reset."
::= { itmex2atvTest 2 }
itmex2atvTestscarrierFrequencyOffset OBJECT-TYPE
SYNTAX Integer32 ( -4000000 .. 4000000 )
UNITS "1 Hz"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Control frequency offset of the single carrier test signal."
::= { itmex2atvTest 4 }
itmex2atvTestColorBurst OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the test signal shall use color burst. This
value is saved in non-volatile memory and thus survives a reboot.
- onOffArray[TEXT_INDEX_OFF] Color burst OFF - onOffArray[TEXT_INDEX_ON]
Color burst ON"
::= { itmex2atvTest 5 }
--
-- itmex2atv Alarm sub-tree
--
-- Group Alarm table --
itmex2atvGroupAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvGroupAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the group alarms"
::= { itmex2atvAlarm 1 }
itmex2atvGroupAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvGroupAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvGroupAlarmID }
::= { itmex2atvGroupAlarmTable 1 }
Itmex2atvGroupAlarmEntry ::= SEQUENCE {
itmex2atvGroupAlarmID Integer32,
itmex2atvGroupAlarmDescription DisplayString,
itmex2atvGroupAlarmState INTEGER,
itmex2atvGroupAlarmActionEventlog INTEGER,
itmex2atvGroupAlarmActionRelay1 INTEGER,
itmex2atvGroupAlarmActionRelay2 INTEGER,
itmex2atvGroupAlarmActionTrap INTEGER,
itmex2atvGroupAlarmActionEmail INTEGER,
itmex2atvGroupAlarmActionAlarmLED INTEGER,
itmex2atvGroupAlarmActionForceMode INTEGER
}
itmex2atvGroupAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvGroupAlarmEntry 1 }
itmex2atvGroupAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvGroupAlarmEntry 2 }
itmex2atvGroupAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current GroupAlarm state condition"
::= { itmex2atvGroupAlarmEntry 3 }
itmex2atvGroupAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvGroupAlarmEntry 4 }
itmex2atvGroupAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvGroupAlarmEntry 5 }
itmex2atvGroupAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvGroupAlarmEntry 6 }
itmex2atvGroupAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvGroupAlarmEntry 7 }
itmex2atvGroupAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvGroupAlarmEntry 8 }
itmex2atvGroupAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvGroupAlarmEntry 9 }
itmex2atvGroupAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvGroupAlarmEntry 10 }
-- Primary Alarm table --
itmex2atvPrimaryAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvPrimaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Primary alarms"
::= { itmex2atvAlarm 5 }
itmex2atvPrimaryAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvPrimaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvPrimaryAlarmID }
::= { itmex2atvPrimaryAlarmTable 1 }
Itmex2atvPrimaryAlarmEntry ::= SEQUENCE {
itmex2atvPrimaryAlarmID Integer32,
itmex2atvPrimaryAlarmDescription DisplayString,
itmex2atvPrimaryAlarmState INTEGER,
itmex2atvPrimaryAlarmActionEventlog INTEGER,
itmex2atvPrimaryAlarmActionRelay1 INTEGER,
itmex2atvPrimaryAlarmActionRelay2 INTEGER,
itmex2atvPrimaryAlarmActionTrap INTEGER,
itmex2atvPrimaryAlarmActionEmail INTEGER,
itmex2atvPrimaryAlarmActionAlarmLED INTEGER,
itmex2atvPrimaryAlarmActionForceMode INTEGER
}
itmex2atvPrimaryAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvPrimaryAlarmEntry 1 }
itmex2atvPrimaryAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvPrimaryAlarmEntry 2 }
itmex2atvPrimaryAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current PrimaryAlarm state condition"
::= { itmex2atvPrimaryAlarmEntry 3 }
itmex2atvPrimaryAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvPrimaryAlarmEntry 4 }
itmex2atvPrimaryAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvPrimaryAlarmEntry 5 }
itmex2atvPrimaryAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvPrimaryAlarmEntry 6 }
itmex2atvPrimaryAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvPrimaryAlarmEntry 7 }
itmex2atvPrimaryAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvPrimaryAlarmEntry 8 }
itmex2atvPrimaryAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvPrimaryAlarmEntry 9 }
itmex2atvPrimaryAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvPrimaryAlarmEntry 10 }
-- Secondary Alarm table --
itmex2atvSecondaryAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvSecondaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Input Signal alarms"
::= { itmex2atvAlarm 6 }
itmex2atvSecondaryAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvSecondaryAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvSecondaryAlarmID }
::= { itmex2atvSecondaryAlarmTable 1 }
Itmex2atvSecondaryAlarmEntry ::= SEQUENCE {
itmex2atvSecondaryAlarmID Integer32,
itmex2atvSecondaryAlarmDescription DisplayString,
itmex2atvSecondaryAlarmState INTEGER,
itmex2atvSecondaryAlarmActionEventlog INTEGER,
itmex2atvSecondaryAlarmActionRelay1 INTEGER,
itmex2atvSecondaryAlarmActionRelay2 INTEGER,
itmex2atvSecondaryAlarmActionTrap INTEGER,
itmex2atvSecondaryAlarmActionEmail INTEGER,
itmex2atvSecondaryAlarmActionAlarmLED INTEGER,
itmex2atvSecondaryAlarmActionForceMode INTEGER
}
itmex2atvSecondaryAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvSecondaryAlarmEntry 1 }
itmex2atvSecondaryAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvSecondaryAlarmEntry 2 }
itmex2atvSecondaryAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current SecondaryAlarm state condition"
::= { itmex2atvSecondaryAlarmEntry 3 }
itmex2atvSecondaryAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvSecondaryAlarmEntry 4 }
itmex2atvSecondaryAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvSecondaryAlarmEntry 5 }
itmex2atvSecondaryAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvSecondaryAlarmEntry 6 }
itmex2atvSecondaryAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvSecondaryAlarmEntry 7 }
itmex2atvSecondaryAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvSecondaryAlarmEntry 8 }
itmex2atvSecondaryAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvSecondaryAlarmEntry 9 }
itmex2atvSecondaryAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvSecondaryAlarmEntry 10 }
-- SFN Alarm table --
itmex2atvSFNAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvSFNAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the SFN alarms"
::= { itmex2atvAlarm 7 }
itmex2atvSFNAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvSFNAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvSFNAlarmID }
::= { itmex2atvSFNAlarmTable 1 }
Itmex2atvSFNAlarmEntry ::= SEQUENCE {
itmex2atvSFNAlarmID Integer32,
itmex2atvSFNAlarmDescription DisplayString,
itmex2atvSFNAlarmState INTEGER,
itmex2atvSFNAlarmActionEventlog INTEGER,
itmex2atvSFNAlarmActionRelay1 INTEGER,
itmex2atvSFNAlarmActionRelay2 INTEGER,
itmex2atvSFNAlarmActionTrap INTEGER,
itmex2atvSFNAlarmActionEmail INTEGER,
itmex2atvSFNAlarmActionAlarmLED INTEGER,
itmex2atvSFNAlarmActionForceMode INTEGER
}
itmex2atvSFNAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvSFNAlarmEntry 1 }
itmex2atvSFNAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvSFNAlarmEntry 2 }
itmex2atvSFNAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current SFNAlarm state condition"
::= { itmex2atvSFNAlarmEntry 3 }
itmex2atvSFNAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvSFNAlarmEntry 4 }
itmex2atvSFNAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvSFNAlarmEntry 5 }
itmex2atvSFNAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvSFNAlarmEntry 6 }
itmex2atvSFNAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvSFNAlarmEntry 7 }
itmex2atvSFNAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvSFNAlarmEntry 8 }
itmex2atvSFNAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvSFNAlarmEntry 9 }
itmex2atvSFNAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvSFNAlarmEntry 10 }
-- Reference Alarm table --
itmex2atvReferenceAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvReferenceAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Reference alarms"
::= { itmex2atvAlarm 8 }
itmex2atvReferenceAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvReferenceAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvReferenceAlarmID }
::= { itmex2atvReferenceAlarmTable 1 }
Itmex2atvReferenceAlarmEntry ::= SEQUENCE {
itmex2atvReferenceAlarmID Integer32,
itmex2atvReferenceAlarmDescription DisplayString,
itmex2atvReferenceAlarmState INTEGER,
itmex2atvReferenceAlarmActionEventlog INTEGER,
itmex2atvReferenceAlarmActionRelay1 INTEGER,
itmex2atvReferenceAlarmActionRelay2 INTEGER,
itmex2atvReferenceAlarmActionTrap INTEGER,
itmex2atvReferenceAlarmActionEmail INTEGER,
itmex2atvReferenceAlarmActionAlarmLED INTEGER,
itmex2atvReferenceAlarmActionForceMode INTEGER
}
itmex2atvReferenceAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvReferenceAlarmEntry 1 }
itmex2atvReferenceAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvReferenceAlarmEntry 2 }
itmex2atvReferenceAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ReferenceAlarm state condition"
::= { itmex2atvReferenceAlarmEntry 3 }
itmex2atvReferenceAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvReferenceAlarmEntry 4 }
itmex2atvReferenceAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvReferenceAlarmEntry 5 }
itmex2atvReferenceAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvReferenceAlarmEntry 6 }
itmex2atvReferenceAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvReferenceAlarmEntry 7 }
itmex2atvReferenceAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvReferenceAlarmEntry 8 }
itmex2atvReferenceAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvReferenceAlarmEntry 9 }
itmex2atvReferenceAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvReferenceAlarmEntry 10 }
-- RF Alarm table --
itmex2atvRFAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvRFAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the RF alarms"
::= { itmex2atvAlarm 9 }
itmex2atvRFAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvRFAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvRFAlarmID }
::= { itmex2atvRFAlarmTable 1 }
Itmex2atvRFAlarmEntry ::= SEQUENCE {
itmex2atvRFAlarmID Integer32,
itmex2atvRFAlarmDescription DisplayString,
itmex2atvRFAlarmState INTEGER,
itmex2atvRFAlarmActionEventlog INTEGER,
itmex2atvRFAlarmActionRelay1 INTEGER,
itmex2atvRFAlarmActionRelay2 INTEGER,
itmex2atvRFAlarmActionTrap INTEGER,
itmex2atvRFAlarmActionEmail INTEGER,
itmex2atvRFAlarmActionAlarmLED INTEGER,
itmex2atvRFAlarmActionForceMode INTEGER
}
itmex2atvRFAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvRFAlarmEntry 1 }
itmex2atvRFAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvRFAlarmEntry 2 }
itmex2atvRFAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current RFAlarm state condition"
::= { itmex2atvRFAlarmEntry 3 }
itmex2atvRFAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvRFAlarmEntry 4 }
itmex2atvRFAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvRFAlarmEntry 5 }
itmex2atvRFAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvRFAlarmEntry 6 }
itmex2atvRFAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvRFAlarmEntry 7 }
itmex2atvRFAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvRFAlarmEntry 8 }
itmex2atvRFAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvRFAlarmEntry 9 }
itmex2atvRFAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvRFAlarmEntry 10 }
-- GPS Alarm table --
itmex2atvGPSAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvGPSAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the GPS alarms"
::= { itmex2atvAlarm 10 }
itmex2atvGPSAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvGPSAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvGPSAlarmID }
::= { itmex2atvGPSAlarmTable 1 }
Itmex2atvGPSAlarmEntry ::= SEQUENCE {
itmex2atvGPSAlarmID Integer32,
itmex2atvGPSAlarmDescription DisplayString,
itmex2atvGPSAlarmState INTEGER,
itmex2atvGPSAlarmActionEventlog INTEGER,
itmex2atvGPSAlarmActionRelay1 INTEGER,
itmex2atvGPSAlarmActionRelay2 INTEGER,
itmex2atvGPSAlarmActionTrap INTEGER,
itmex2atvGPSAlarmActionEmail INTEGER,
itmex2atvGPSAlarmActionAlarmLED INTEGER,
itmex2atvGPSAlarmActionForceMode INTEGER
}
itmex2atvGPSAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvGPSAlarmEntry 1 }
itmex2atvGPSAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvGPSAlarmEntry 2 }
itmex2atvGPSAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current GPSAlarm state condition"
::= { itmex2atvGPSAlarmEntry 3 }
itmex2atvGPSAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvGPSAlarmEntry 4 }
itmex2atvGPSAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvGPSAlarmEntry 5 }
itmex2atvGPSAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvGPSAlarmEntry 6 }
itmex2atvGPSAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvGPSAlarmEntry 7 }
itmex2atvGPSAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvGPSAlarmEntry 8 }
itmex2atvGPSAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvGPSAlarmEntry 9 }
itmex2atvGPSAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvGPSAlarmEntry 10 }
-- External Alarm table --
itmex2atvExternalAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvExternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the External alarms"
::= { itmex2atvAlarm 13 }
itmex2atvExternalAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvExternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvExternalAlarmID }
::= { itmex2atvExternalAlarmTable 1 }
Itmex2atvExternalAlarmEntry ::= SEQUENCE {
itmex2atvExternalAlarmID Integer32,
itmex2atvExternalAlarmDescription DisplayString,
itmex2atvExternalAlarmState INTEGER,
itmex2atvExternalAlarmActionEventlog INTEGER,
itmex2atvExternalAlarmActionRelay1 INTEGER,
itmex2atvExternalAlarmActionRelay2 INTEGER,
itmex2atvExternalAlarmActionTrap INTEGER,
itmex2atvExternalAlarmActionEmail INTEGER,
itmex2atvExternalAlarmActionAlarmLED INTEGER,
itmex2atvExternalAlarmActionForceMode INTEGER
}
itmex2atvExternalAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvExternalAlarmEntry 1 }
itmex2atvExternalAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvExternalAlarmEntry 2 }
itmex2atvExternalAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current ExternalAlarm state condition"
::= { itmex2atvExternalAlarmEntry 3 }
itmex2atvExternalAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvExternalAlarmEntry 4 }
itmex2atvExternalAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvExternalAlarmEntry 5 }
itmex2atvExternalAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvExternalAlarmEntry 6 }
itmex2atvExternalAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvExternalAlarmEntry 7 }
itmex2atvExternalAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvExternalAlarmEntry 8 }
itmex2atvExternalAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvExternalAlarmEntry 9 }
itmex2atvExternalAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvExternalAlarmEntry 10 }
-- HW Monitor Alarm table --
itmex2atvHWMonitorAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvHWMonitorAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the HW Monitor alarms"
::= { itmex2atvAlarm 14 }
itmex2atvHWMonitorAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvHWMonitorAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvHWMonitorAlarmID }
::= { itmex2atvHWMonitorAlarmTable 1 }
Itmex2atvHWMonitorAlarmEntry ::= SEQUENCE {
itmex2atvHWMonitorAlarmID Integer32,
itmex2atvHWMonitorAlarmDescription DisplayString,
itmex2atvHWMonitorAlarmState INTEGER,
itmex2atvHWMonitorAlarmActionEventlog INTEGER,
itmex2atvHWMonitorAlarmActionRelay1 INTEGER,
itmex2atvHWMonitorAlarmActionRelay2 INTEGER,
itmex2atvHWMonitorAlarmActionTrap INTEGER,
itmex2atvHWMonitorAlarmActionEmail INTEGER,
itmex2atvHWMonitorAlarmActionAlarmLED INTEGER,
itmex2atvHWMonitorAlarmActionForceMode INTEGER
}
itmex2atvHWMonitorAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvHWMonitorAlarmEntry 1 }
itmex2atvHWMonitorAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvHWMonitorAlarmEntry 2 }
itmex2atvHWMonitorAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current HWMonitorAlarm state condition"
::= { itmex2atvHWMonitorAlarmEntry 3 }
itmex2atvHWMonitorAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvHWMonitorAlarmEntry 4 }
itmex2atvHWMonitorAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvHWMonitorAlarmEntry 5 }
itmex2atvHWMonitorAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvHWMonitorAlarmEntry 6 }
itmex2atvHWMonitorAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvHWMonitorAlarmEntry 7 }
itmex2atvHWMonitorAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvHWMonitorAlarmEntry 8 }
itmex2atvHWMonitorAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvHWMonitorAlarmEntry 9 }
itmex2atvHWMonitorAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvHWMonitorAlarmEntry 10 }
-- Communications Alarm table --
itmex2atvCommsAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvCommsAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Communication alarms"
::= { itmex2atvAlarm 15 }
itmex2atvCommsAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvCommsAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvCommsAlarmID }
::= { itmex2atvCommsAlarmTable 1 }
Itmex2atvCommsAlarmEntry ::= SEQUENCE {
itmex2atvCommsAlarmID Integer32,
itmex2atvCommsAlarmDescription DisplayString,
itmex2atvCommsAlarmState INTEGER,
itmex2atvCommsAlarmActionEventlog INTEGER,
itmex2atvCommsAlarmActionRelay1 INTEGER,
itmex2atvCommsAlarmActionRelay2 INTEGER,
itmex2atvCommsAlarmActionTrap INTEGER,
itmex2atvCommsAlarmActionEmail INTEGER,
itmex2atvCommsAlarmActionAlarmLED INTEGER,
itmex2atvCommsAlarmActionForceMode INTEGER
}
itmex2atvCommsAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvCommsAlarmEntry 1 }
itmex2atvCommsAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvCommsAlarmEntry 2 }
itmex2atvCommsAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current CommsAlarm state condition"
::= { itmex2atvCommsAlarmEntry 3 }
itmex2atvCommsAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvCommsAlarmEntry 4 }
itmex2atvCommsAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvCommsAlarmEntry 5 }
itmex2atvCommsAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvCommsAlarmEntry 6 }
itmex2atvCommsAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvCommsAlarmEntry 7 }
itmex2atvCommsAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvCommsAlarmEntry 8 }
itmex2atvCommsAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvCommsAlarmEntry 9 }
itmex2atvCommsAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvCommsAlarmEntry 10 }
-- Internal Alarm table --
itmex2atvInternalAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvInternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the Internal alarms"
::= { itmex2atvAlarm 18 }
itmex2atvInternalAlarmEntry OBJECT-TYPE
SYNTAX Itmex2atvInternalAlarmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvInternalAlarmID }
::= { itmex2atvInternalAlarmTable 1 }
Itmex2atvInternalAlarmEntry ::= SEQUENCE {
itmex2atvInternalAlarmID Integer32,
itmex2atvInternalAlarmDescription DisplayString,
itmex2atvInternalAlarmState INTEGER,
itmex2atvInternalAlarmActionEventlog INTEGER,
itmex2atvInternalAlarmActionRelay1 INTEGER,
itmex2atvInternalAlarmActionRelay2 INTEGER,
itmex2atvInternalAlarmActionTrap INTEGER,
itmex2atvInternalAlarmActionEmail INTEGER,
itmex2atvInternalAlarmActionAlarmLED INTEGER,
itmex2atvInternalAlarmActionForceMode INTEGER
}
itmex2atvInternalAlarmID OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 255 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this alarm"
::= { itmex2atvInternalAlarmEntry 1 }
itmex2atvInternalAlarmDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description for this alarm"
::= { itmex2atvInternalAlarmEntry 2 }
itmex2atvInternalAlarmState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current InternalAlarm state condition"
::= { itmex2atvInternalAlarmEntry 3 }
itmex2atvInternalAlarmActionEventlog OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an event in the eventlog"
::= { itmex2atvInternalAlarmEntry 4 }
itmex2atvInternalAlarmActionRelay1 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay1"
::= { itmex2atvInternalAlarmEntry 5 }
itmex2atvInternalAlarmActionRelay2 OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm activate relay2"
::= { itmex2atvInternalAlarmEntry 6 }
itmex2atvInternalAlarmActionTrap OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate a trap"
::= { itmex2atvInternalAlarmEntry 7 }
itmex2atvInternalAlarmActionEmail OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm generate an email"
::= { itmex2atvInternalAlarmEntry 8 }
itmex2atvInternalAlarmActionAlarmLED OBJECT-TYPE
SYNTAX INTEGER { disabled(0), enabled(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm turn Alarm LED on frontpanel on"
::= { itmex2atvInternalAlarmEntry 9 }
itmex2atvInternalAlarmActionForceMode OBJECT-TYPE
SYNTAX INTEGER { none(0), mute(1), reboot(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the current alarm mute output"
::= { itmex2atvInternalAlarmEntry 10 }
-- DVB-T2 Mode-A Alarm table --
--
-- itmex2atv Preset sub-tree
--
itmex2atvPresetTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvPresetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the presets"
::= { itmex2atvPreset 1 }
itmex2atvPresetEntry OBJECT-TYPE
SYNTAX Itmex2atvPresetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the presets"
INDEX { itmex2atvPresetNo }
::= { itmex2atvPresetTable 1 }
Itmex2atvPresetEntry ::= SEQUENCE {
itmex2atvPresetNo Integer32,
itmex2atvPresetName DisplayString
}
itmex2atvPresetNo OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 10 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique number for this preset"
::= { itmex2atvPresetEntry 1 }
itmex2atvPresetName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for this preset"
::= { itmex2atvPresetEntry 2 }
itmex2atvPresetRecall OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Install this preset into current running parameter set.
Value will always read as 0 and setting it to 0 has no effect."
::= { itmex2atvPreset 2 }
itmex2atvPresetStore OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 8 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Store the currently running parameter set into this preset
Value will always read as 0 and setting it to 0 has no effect."
::= { itmex2atvPreset 3 }
itmex2atvPresetLastRecalled OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the last recalled preset."
::= { itmex2atvPreset 4 }
--
-- itmex2atv Eventlog sub-tree
--
itmex2atvEventlogTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvEventlogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the group alarms"
::= { itmex2atvEventlog 1 }
itmex2atvEventlogEntry OBJECT-TYPE
SYNTAX Itmex2atvEventlogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the alarms"
INDEX { itmex2atvEventlogNo }
::= { itmex2atvEventlogTable 1 }
Itmex2atvEventlogEntry ::= SEQUENCE {
itmex2atvEventlogNo Integer32,
itmex2atvEventlogID Integer32,
itmex2atvEventlogTimestamp DateAndTime,
itmex2atvEventlogText DisplayString
}
itmex2atvEventlogNo OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 2047 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique number for this event"
::= { itmex2atvEventlogEntry 1 }
itmex2atvEventlogID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique ID for this type of event"
::= { itmex2atvEventlogEntry 2 }
itmex2atvEventlogTimestamp OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Timestamp for this event"
::= { itmex2atvEventlogEntry 3 }
itmex2atvEventlogText OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Text for this event"
::= { itmex2atvEventlogEntry 4 }
itmex2atvEventlogClear OBJECT-TYPE
SYNTAX INTEGER { noop(0), clear(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the entire eventlog by setting the value to 1."
::= { itmex2atvEventlog 2 }
itmex2atvEventlogEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable eventlog by setting the value to 1."
::= { itmex2atvEventlog 3 }
itmex2atvEventlogMode OBJECT-TYPE
SYNTAX INTEGER { fifo(0), full(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set eventlog mode to FIFO for keeping the newest entries.
Set eventlog mode to FULL for keeping the oldest entries."
::= { itmex2atvEventlog 4 }
--
-- itmex2atv Comms sub-tree
--
itmex2atvCommsAlarmEmailReceiver OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The email address of the receipiant of alarm emails."
::= { itmex2atvComms 34 }
itmex2atvCommsNetworkWarnings OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Warnings about the network configuration."
::= { itmex2atvComms 888 }
itmex2atvCommsSeparatedSwitchPorts OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Will the ports on the switch in the backplane forward LAN traffic
to each other or will they be separated and only forward traffic
to/from the modulator/repeater."
::= { itmex2atvComms 98 }
itmex2atvCommsBroadcastStormProtection OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable broadcast (and multicast) storm Protection. This
will limit the network ingress rate on physical Ethernet port
0 and 1 to roughly 100mbit/s."
::= { itmex2atvComms 94 }
itmex2atvCommsLocalPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { itmex2atvComms 80 }
itmex2atvCommsLocalDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { itmex2atvComms 3 }
itmex2atvCommsLocalStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 1 }
itmex2atvCommsLocalStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 2 }
itmex2atvCommsLocalVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { itmex2atvComms 101 }
itmex2atvCommsLocalVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { itmex2atvComms 102 }
itmex2atvCommsLocalServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { itmex2atvComms 103 }
itmex2atvCommsLocalServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { itmex2atvComms 104 }
itmex2atvCommsLocalServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { itmex2atvComms 105 }
itmex2atvCommsLocalServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { itmex2atvComms 106 }
itmex2atvCommsLocalCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { itmex2atvComms 4 }
itmex2atvCommsLocalCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { itmex2atvComms 5 }
itmex2atvCommsRemoteEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { itmex2atvComms 117 }
itmex2atvCommsRemotePhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { itmex2atvComms 81 }
itmex2atvCommsRemoteDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { itmex2atvComms 73 }
itmex2atvCommsRemoteStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 7 }
itmex2atvCommsRemoteStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 8 }
itmex2atvCommsRemoteVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { itmex2atvComms 111 }
itmex2atvCommsRemoteVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { itmex2atvComms 112 }
itmex2atvCommsRemoteServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { itmex2atvComms 113 }
itmex2atvCommsRemoteServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { itmex2atvComms 114 }
itmex2atvCommsRemoteServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { itmex2atvComms 115 }
itmex2atvCommsRemoteServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable WEB (http) service on this interface."
::= { itmex2atvComms 116 }
itmex2atvCommsRemoteServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { itmex2atvComms 118 }
itmex2atvCommsRemoteCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { itmex2atvComms 10 }
itmex2atvCommsRemoteCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { itmex2atvComms 11 }
itmex2atvCommsGbeAdminEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { itmex2atvComms 127 }
itmex2atvCommsGbeAdminPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { itmex2atvComms 82 }
itmex2atvCommsGbeAdminDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { itmex2atvComms 74 }
itmex2atvCommsGbeAdminStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 13 }
itmex2atvCommsGbeAdminStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 14 }
itmex2atvCommsGbeAdminVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { itmex2atvComms 121 }
itmex2atvCommsGbeAdminVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { itmex2atvComms 122 }
itmex2atvCommsGbeAdminServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { itmex2atvComms 123 }
itmex2atvCommsGbeAdminServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { itmex2atvComms 124 }
itmex2atvCommsGbeAdminServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { itmex2atvComms 125 }
itmex2atvCommsGbeAdminServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Web (http) service on this interface."
::= { itmex2atvComms 126 }
itmex2atvCommsGbeAdminServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { itmex2atvComms 128 }
itmex2atvCommsGbeAdminCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { itmex2atvComms 16 }
itmex2atvCommsGbeAdminCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { itmex2atvComms 17 }
itmex2atvCommsBackupEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { itmex2atvComms 150 }
itmex2atvCommsBackupPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { itmex2atvComms 151 }
itmex2atvCommsBackupDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { itmex2atvComms 75 }
itmex2atvCommsBackupStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 152 }
itmex2atvCommsBackupStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 153 }
itmex2atvCommsBackupVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { itmex2atvComms 155 }
itmex2atvCommsBackupVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { itmex2atvComms 156 }
itmex2atvCommsBackupServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { itmex2atvComms 157 }
itmex2atvCommsBackupServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { itmex2atvComms 158 }
itmex2atvCommsBackupServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { itmex2atvComms 159 }
itmex2atvCommsBackupServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Web (http) service on this interface."
::= { itmex2atvComms 160 }
itmex2atvCommsBackupServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { itmex2atvComms 161 }
itmex2atvCommsBackupCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { itmex2atvComms 162 }
itmex2atvCommsBackupCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { itmex2atvComms 163 }
itmex2atvCommsPortEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable this interface."
::= { itmex2atvComms 2500 }
itmex2atvCommsPortPhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface of this (virtual) interface."
::= { itmex2atvComms 2151 }
itmex2atvCommsPortDhcpMode OBJECT-TYPE
SYNTAX INTEGER { off(0), client(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable DHCP client on this interface."
::= { itmex2atvComms 2075 }
itmex2atvCommsPortStaticIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 2152 }
itmex2atvCommsPortStaticNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP netmask for this interface. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 2153 }
itmex2atvCommsPortVlanEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable VLAN on this interface."
::= { itmex2atvComms 2155 }
itmex2atvCommsPortVlanId OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4095 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN ID to use on this interface, if VLAN is enabled. Please
note that VLAN ID 4001 and 4002 are used for internal switching
and thus cannot be used on any interface."
::= { itmex2atvComms 2156 }
itmex2atvCommsPortServiceSNMP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SNMP service on this interface."
::= { itmex2atvComms 2157 }
itmex2atvCommsPortServiceSCPI OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable SCPI service on this interface."
::= { itmex2atvComms 2158 }
itmex2atvCommsPortServiceTSoIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable TSoIP service on this interface."
::= { itmex2atvComms 2159 }
itmex2atvCommsPortServiceWeb OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Web (http) service on this interface."
::= { itmex2atvComms 2160 }
itmex2atvCommsPortServiceRIP OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable RIP service on this interface."
::= { itmex2atvComms 2161 }
itmex2atvCommsPortCurrentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP address for this interface."
::= { itmex2atvComms 2162 }
itmex2atvCommsPortCurrentNetmask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current IP netmask for this interface."
::= { itmex2atvComms 2163 }
itmex2atvCommsSNMPServicePort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for SNMP Service."
::= { itmex2atvComms 55 }
itmex2atvCommsSNMPReadOnlyCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Read-only community string used to access the SNMP Service."
::= { itmex2atvComms 56 }
itmex2atvCommsSNMPReadWriteCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Read-Write community string used to access the SNMP Service."
::= { itmex2atvComms 57 }
itmex2atvCommsSNMPTrapCommunity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Trap community string used when sending SNMP Traps."
::= { itmex2atvComms 58 }
itmex2atvCommsSNMPTrapDestination OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination IP address for the SNMP traps."
::= { itmex2atvComms 59 }
itmex2atvCommsSNMPTrapDestination2 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 2 IP address for the SNMP traps."
::= { itmex2atvComms 419 }
itmex2atvCommsSNMPTrapDestination3 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 3 IP address for the SNMP traps."
::= { itmex2atvComms 779 }
itmex2atvCommsSNMPTrapDestination4 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 4 IP address for the SNMP traps."
::= { itmex2atvComms 1139 }
itmex2atvCommsSNMPTrapDestination5 OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The destination 5 IP address for the SNMP traps."
::= { itmex2atvComms 1499 }
itmex2atvCommsSNMPTrapDestinationPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination ."
::= { itmex2atvComms 60 }
itmex2atvCommsSNMPTrapDestinationPort2 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 2."
::= { itmex2atvComms 420 }
itmex2atvCommsSNMPTrapDestinationPort3 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 3."
::= { itmex2atvComms 780 }
itmex2atvCommsSNMPTrapDestinationPort4 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 4."
::= { itmex2atvComms 1140 }
itmex2atvCommsSNMPTrapDestinationPort5 OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for Trap destination 5."
::= { itmex2atvComms 1500 }
itmex2atvCommsStaticGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static IP address for the default router (gateway). Will
be used unless DHCP is enabled and the DHCP server is configured
to include a default router address."
::= { itmex2atvComms 29 }
itmex2atvCommsCurrentGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address for the default router (gateway)."
::= { itmex2atvComms 30 }
itmex2atvCommsStaticHostname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static hostname for the device. Will be used if DHCP is
disabled or unavailable."
::= { itmex2atvComms 27 }
itmex2atvCommsCurrentHostname OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The static hostname for the device. Will be used if DHCP is
disabled or unavailable."
::= { itmex2atvComms 28 }
itmex2atvCommsStaticDNSDomain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The static DNS domain name for the device. Will be used if DHCP
is disabled or unavailable."
::= { itmex2atvComms 25 }
itmex2atvCommsCurrentDNSDomain OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current DNS domain name for the device."
::= { itmex2atvComms 26 }
itmex2atvCommsStaticDNS1ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of DNS server 1."
::= { itmex2atvComms 19 }
itmex2atvCommsStaticDNS2ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of DNS server 2."
::= { itmex2atvComms 21 }
itmex2atvCommsStaticDNS3ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of DNS server 3."
::= { itmex2atvComms 23 }
itmex2atvCommsCurrentDNS1ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of DNS server 1."
::= { itmex2atvComms 20 }
itmex2atvCommsCurrentDNS2ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of DNS server 2."
::= { itmex2atvComms 22 }
itmex2atvCommsCurrentDNS3ServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of DNS server 3."
::= { itmex2atvComms 24 }
itmex2atvCommsStaticNtpServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DNS name or IP address of NTP server 1."
::= { itmex2atvComms 31 }
itmex2atvCommsStaticNtp2ServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DNS name or IP address of NTP server 2."
::= { itmex2atvComms 3102 }
itmex2atvCommsStaticNtp3ServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The DNS name or IP address of NTP server 3."
::= { itmex2atvComms 3104 }
itmex2atvCommsCurrentNtpServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of NTP server 1."
::= { itmex2atvComms 32 }
itmex2atvCommsCurrentNtp2ServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of NTP server 2."
::= { itmex2atvComms 3202 }
itmex2atvCommsCurrentNtp3ServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Current IP address of NTP server 3."
::= { itmex2atvComms 3204 }
itmex2atvCommsEmailServerAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the Email (SMTP) server."
::= { itmex2atvComms 33 }
itmex2atvCommsSecureWebPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number used for Web Service in HTTPS."
::= { itmex2atvComms 9940 }
itmex2atvCommsWebProto OBJECT-TYPE
SYNTAX INTEGER { both(0), https(1), http(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol for web access."
::= { itmex2atvComms 9941 }
itmex2atvCommsWebServicePort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number used for Web Service."
::= { itmex2atvComms 35 }
itmex2atvCommsSCPIServicePort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The TCP port number used for SCPI Service."
::= { itmex2atvComms 36 }
itmex2atvCommsSCPIServerBaudrate OBJECT-TYPE
SYNTAX INTEGER { r2400(0), r4800(1), r9600(2), r19200(3), r38400(4), r57600(5), r115200(6) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Baudrate used for SCPI Service on serial port."
::= { itmex2atvComms 37 }
itmex2atvCommsSCPIUartInterface OBJECT-TYPE
SYNTAX INTEGER { rs232(0), rs485(1), rs485hd(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Interface used for SCPI Service on serial port."
::= { itmex2atvComms 39 }
itmex2atvCommsRipPort OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port number used for RIP Service."
::= { itmex2atvComms 38 }
itmex2atvCommsIGMPVersion OBJECT-TYPE
SYNTAX INTEGER { auto(0), v1(1), v2(2), v3(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Select which IGMP Version to use."
::= { itmex2atvComms 99 }
itmex2atvCommsIGMPQueryRobustnessCount OBJECT-TYPE
SYNTAX Integer32 ( 2 .. 16 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Number of Query Replies sent. The higher a number, the more
robust IGMP setup is. At the cost of traffic on the network.
Note: Changing this parameter doesnt take effect on a network
interface until it has (re-)enabled."
::= { itmex2atvComms 97 }
itmex2atvCommsIGMPv3UnsolicitedReportInterval OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 60000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval between unsolicited IGMPv3 reports being sent.
See RFC3376. The number of such report being sent is controlled
by the Query Robustness Count."
::= { itmex2atvComms 96 }
itmex2atvCommsIGMPv2UnsolicitedReportInterval OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 60000 )
UNITS "1 ms"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval between unsolicited IGMPv2/v1 reports being
sent. See RFC2236. The number of such report being sent is
controlled by the Query Robustness Count."
::= { itmex2atvComms 95 }
itmex2atvCommsAccessAllowed OBJECT-TYPE
SYNTAX INTEGER { remote(0), local-disable-set(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Current access mode allowed: Remote: SNMP via Ethernet, Local:
Frontpanel"
::= { itmex2atvComms 48 }
itmex2atvCommsAccessAllowedTimeout OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 1440 )
UNITS "1 min"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Timeout (in minutes) before local mode reverts to remote mode."
::= { itmex2atvComms 49 }
itmex2atvCommsAccessAllowedTimeLeft OBJECT-TYPE
SYNTAX Integer32
UNITS "1 secs"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Current time left (in seconds) before local mode reverts to
remote mode."
::= { itmex2atvComms 50 }
itmex2atvCommsNtpStatusMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The latest NTP Protocol status message."
::= { itmex2atvComms 1000 }
itmex2atvCommsNtpStatusLeapsec OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The latest Leap-Second status message."
::= { itmex2atvComms 1001 }
itmex2atvCommsNtpStatusSource OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The original clock source type as related by peer."
::= { itmex2atvComms 1002 }
itmex2atvCommsNtpPeerRmsJitter OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RMS Jitter between the NTP server (peer) and this unit."
::= { itmex2atvComms 1003 }
itmex2atvCommsNtpPeerClockOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The clock offset between the NTP server (peer) and this unit."
::= { itmex2atvComms 1004 }
itmex2atvCommsNtpPeerRoundtripDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Round-Trip delay between the NTP server (peer) and this
unit."
::= { itmex2atvComms 1005 }
itmex2atvCommsNtpPeerDispertion OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The dispersion between the NTP server (peer) and this unit."
::= { itmex2atvComms 1006 }
itmex2atvCommsNtpLoopRmsJitter OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RMS Jitter in the loop of this unit."
::= { itmex2atvComms 1007 }
itmex2atvCommsNtpLoopClockOffset OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 ms"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The clock offset between the loop of this unit and the real
time."
::= { itmex2atvComms 1008 }
itmex2atvCommsNtpLoopRmsWander OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 PPM"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The RMS wander between loop of this unit and the real time."
::= { itmex2atvComms 1009 }
itmex2atvCommsNtpLoopFreqOff OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 PPM"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The frequency offset between loop of this unit and the real
time."
::= { itmex2atvComms 1010 }
itmex2atvCommsAccessPasswordObserver OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access password for Observer level access. Will always read as empty."
::= { itmex2atvComms 51 }
itmex2atvCommsAccessPasswordOperator OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access password for Operator level access. Will always read as empty."
::= { itmex2atvComms 52 }
itmex2atvCommsAccessPasswordAdministrator OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The access password for Administrator level access. Will always read as empty."
::= { itmex2atvComms 53 }
itmex2atvCommsStaticRouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF Itmex2atvCommsStaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the static routing table entries"
::= { itmex2atvComms 300 }
itmex2atvCommsStaticRouteEntry OBJECT-TYPE
SYNTAX Itmex2atvCommsStaticRouteEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry for the static network routing table"
INDEX { itmex2atvCommsStaticRouteNO }
::= { itmex2atvCommsStaticRouteTable 1 }
Itmex2atvCommsStaticRouteEntry ::= SEQUENCE {
itmex2atvCommsStaticRouteNO Integer32,
itmex2atvCommsStaticRouteType INTEGER,
itmex2atvCommsStaticRoutePrefix IpAddress,
itmex2atvCommsStaticRoutePrefixSize Integer32,
itmex2atvCommsStaticRouteTarget IpAddress,
itmex2atvCommsStaticRoutePhysicalInterface INTEGER
}
itmex2atvCommsStaticRouteNO OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 16 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique ID for this static route entry"
::= { itmex2atvCommsStaticRouteEntry 1 }
itmex2atvCommsStaticRouteType OBJECT-TYPE
SYNTAX INTEGER { unused(0), normal(1), physicalif(2), recursive(3), drop(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Type of a Route table entry."
::= { itmex2atvCommsStaticRouteEntry 2 }
itmex2atvCommsStaticRoutePrefix OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address part of prefix for a route table entry.
If the address is 0.0.0.0, the entry will not be used."
::= { itmex2atvCommsStaticRouteEntry 3 }
itmex2atvCommsStaticRoutePrefixSize OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 32 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of bits in the network part of the prefix for route table entry $.
If the number is 0 (zero), the entry will not be used."
::= { itmex2atvCommsStaticRouteEntry 4 }
itmex2atvCommsStaticRouteTarget OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The target IP address for a route table entry.
Only used if itmex2atvCommsStaticRouteType is normal(1) or recursive(3).
If the target address is 0.0.0.0, the entry will not be used."
::= { itmex2atvCommsStaticRouteEntry 5 }
itmex2atvCommsStaticRoutePhysicalInterface OBJECT-TYPE
SYNTAX INTEGER { eth0(0), eth1(1), eth2(2), eth3(3), eth4(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Physical Ethernet Interface to use for a Route table entry.
Only used when itmex2atvCommsStaticRouteType is physicalif(2)."
::= { itmex2atvCommsStaticRouteEntry 6 }
--
-- itmex2atv Precorrector sub-tree
--
itmex2atvPrecorrectorVersionadaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Adaptive precorrector version."
::= { itmex2atvPrecorrector 100 }
itmex2atvPrecorrectorVersionoptipower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OptiPower version."
::= { itmex2atvPrecorrector 101 }
itmex2atvPrecorrectorHeadroom OBJECT-TYPE
SYNTAX INTEGER { r12(0), r15(1), r18(2), r21(3), r24(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the wanted headroom"
::= { itmex2atvPrecorrector 5 }
itmex2atvPrecorrectorLinearAdaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Linear precorrection curve active in the system"
::= { itmex2atvPrecorrector 79 }
itmex2atvPrecorrectorLinearMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the linear precorrector
(note: legacy term used for backward compatibility. MONITORING
Equal to the mode named BYPASS in the WEB GUI )"
::= { itmex2atvPrecorrector 2 }
itmex2atvPrecorrectorLinearSenseEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By using this, it is possible to control wether to use the linear
Sense Input or not."
::= { itmex2atvPrecorrector 46 }
itmex2atvPrecorrectorLinearMonitorStatus OBJECT-TYPE
SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"linear Precor state"
::= { itmex2atvPrecorrector 24 }
itmex2atvPrecorrectorLinearMonitorSenseLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level meassured at the linear sense input with offset defined
by attenuation"
::= { itmex2atvPrecorrector 22 }
itmex2atvPrecorrectorLinearMonitorSenseValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is linear sense input information valid"
::= { itmex2atvPrecorrector 23 }
itmex2atvPrecorrectorLinearMonitorSenseBadCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bad/invalid sense counts, made by the linear adaptive
precorrector."
::= { itmex2atvPrecorrector 8 }
itmex2atvPrecorrectorLinearMonitorAmplitudeRipple OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amplitude ripple"
::= { itmex2atvPrecorrector 26 }
itmex2atvPrecorrectorLinearMonitorAmplitudeRippleValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is amplitude ripple information valid"
::= { itmex2atvPrecorrector 30 }
itmex2atvPrecorrectorLinearMonitorGroupDelay OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 ns"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Group delay"
::= { itmex2atvPrecorrector 27 }
itmex2atvPrecorrectorLinearMonitorGroupDelayValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is group delay information valid"
::= { itmex2atvPrecorrector 31 }
itmex2atvPrecorrectorLinearMonitorDiscartedIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations discarded by the linear adaptive precorrector
due to noisy signal samples."
::= { itmex2atvPrecorrector 47 }
itmex2atvPrecorrectorLinearMonitorIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations made by the linear adaptive precorrector."
::= { itmex2atvPrecorrector 19 }
itmex2atvPrecorrectorLinearAdapMode OBJECT-TYPE
SYNTAX INTEGER { idle(0), autorun(1), runtotarget(2), continuous(3), single(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the linear adaptive precorrector
(note: legacy term used for backward compatibility. IDLE
Equal to the mode named MONITORING in the WEB GUI )"
::= { itmex2atvPrecorrector 1 }
itmex2atvPrecorrectorLinearAdapAmplitudeRippleTargetLevel OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10000 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the amplitude ripple"
::= { itmex2atvPrecorrector 42 }
itmex2atvPrecorrectorLinearAdapAmplitudeRippleTargetHys OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the amplitude
ripple"
::= { itmex2atvPrecorrector 14 }
itmex2atvPrecorrectorLinearAdapAmplitudeRippleEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable amplitude ripple as a trigger for the AUTORUN and RUNTOTARGET
modes"
::= { itmex2atvPrecorrector 10 }
itmex2atvPrecorrectorLinearAdapGroupDelayTargetLevel OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 10000 )
UNITS "0.1 ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the group delay"
::= { itmex2atvPrecorrector 43 }
itmex2atvPrecorrectorLinearAdapGroupDelayTargetHys OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100000 )
UNITS "0.01 ns"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the group delay"
::= { itmex2atvPrecorrector 15 }
itmex2atvPrecorrectorLinearAdapGroupDelayEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable group delay as a trigger for the AUTORUN and RUNTOTARGET
modes"
::= { itmex2atvPrecorrector 11 }
itmex2atvPrecorrectorLinearAdapPresetNeutralload OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Apply the Neutral spectrum curve"
::= { itmex2atvPrecorrector 82 }
itmex2atvPrecorrectorLinearAdapPresetFactoryrecall OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Recall the stored Factory spectrum curve from memory"
::= { itmex2atvPrecorrector 83 }
itmex2atvPrecorrectorLinearAdapPresetFactorystore OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Store current adptive precorrected spectrum as factory curve"
::= { itmex2atvPrecorrector 84 }
itmex2atvPrecorrectorLinearAdapPresetFactoryclear OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear factory spectrum curve stored in memory to neutral curve"
::= { itmex2atvPrecorrector 85 }
itmex2atvPrecorrectorLinearAttenuation OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a attenuation level for the sense input"
::= { itmex2atvPrecorrector 78 }
itmex2atvPrecorrectorNonlinearAdaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Non-Linear precorrection curve active in the system"
::= { itmex2atvPrecorrector 80 }
itmex2atvPrecorrectorNonlinearMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the non-linear precorrector
(note: legacy term used for backward compatibility. MONITORING
Equal to the mode named BYPASS in the WEB GUI )"
::= { itmex2atvPrecorrector 4 }
itmex2atvPrecorrectorNonlinearSenseEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"By using this, it is possible to control wether to use the nonlinear
Sense Input or not."
::= { itmex2atvPrecorrector 48 }
itmex2atvPrecorrectorNonlinearMonitorStatus OBJECT-TYPE
SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Nonlinear Precor state"
::= { itmex2atvPrecorrector 40 }
itmex2atvPrecorrectorNonlinearMonitorSenseLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Level meassured at the Nonlinear sense input with offset defined
by attenuation"
::= { itmex2atvPrecorrector 38 }
itmex2atvPrecorrectorNonlinearMonitorSenseValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Nonlinear sense input information valid"
::= { itmex2atvPrecorrector 39 }
itmex2atvPrecorrectorNonlinearMonitorSenseBadCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of bad/invalid sense counts, made by the nonlinear adaptive
precorrector."
::= { itmex2atvPrecorrector 9 }
itmex2atvPrecorrectorNonlinearMonitorLowerShoulderLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lower shoulder level"
::= { itmex2atvPrecorrector 28 }
itmex2atvPrecorrectorNonlinearMonitorLowerShoulderValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Lower shoulder information valid"
::= { itmex2atvPrecorrector 32 }
itmex2atvPrecorrectorNonlinearMonitorUpperShoulderLevel OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upper shoulder level"
::= { itmex2atvPrecorrector 29 }
itmex2atvPrecorrectorNonlinearMonitorUpperShoulderValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Upper shoulder information valid"
::= { itmex2atvPrecorrector 33 }
itmex2atvPrecorrectorNonlinearMonitorDiscartedIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations discarded by the non-linear adaptive precorrector
dur to noisy signal samples."
::= { itmex2atvPrecorrector 49 }
itmex2atvPrecorrectorNonlinearMonitorIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of iterations made by the nonlinear adaptive precorrector."
::= { itmex2atvPrecorrector 35 }
itmex2atvPrecorrectorNonlinearMonitorMer OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MER"
::= { itmex2atvPrecorrector 50 }
itmex2atvPrecorrectorNonlinearMonitorMerValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is MER information valid"
::= { itmex2atvPrecorrector 51 }
itmex2atvPrecorrectorNonlinearMonitorPapr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PAPR level"
::= { itmex2atvPrecorrector 52 }
itmex2atvPrecorrectorNonlinearMonitorPaprValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Papr information valid"
::= { itmex2atvPrecorrector 53 }
itmex2atvPrecorrectorNonlinearAttenuation OBJECT-TYPE
SYNTAX Integer32 ( -1000 .. 1000 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a attenuation level for the sense input"
::= { itmex2atvPrecorrector 77 }
itmex2atvPrecorrectorNonlinearAdaptiveMode OBJECT-TYPE
SYNTAX INTEGER { idle(0), autorun(1), runtotarget(2), continuous(3), single(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"selection of the operational mode for the non-linear adaptive
precorrector
(note: legacy term used for backward compatibility.
IDLE Equal to the mode named MONITORING in the WEB GUI )"
::= { itmex2atvPrecorrector 3 }
itmex2atvPrecorrectorNonlinearAdaptiveMaxRfPaprEnable OBJECT-TYPE
SYNTAX INTEGER { disable(0), enable(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable the modulator's output PAPR limiter function"
::= { itmex2atvPrecorrector 55 }
itmex2atvPrecorrectorNonlinearAdaptiveMaxRfPaprLimit OBJECT-TYPE
SYNTAX Integer32 ( 20 .. 180 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum RF PAPR Limitation"
::= { itmex2atvPrecorrector 56 }
itmex2atvPrecorrectorNonlinearAdaptiveMerTarget OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 800 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a target level for the MER"
::= { itmex2atvPrecorrector 57 }
itmex2atvPrecorrectorNonlinearAdaptiveMerTargetHys OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a target MER hysteresis"
::= { itmex2atvPrecorrector 58 }
itmex2atvPrecorrectorNonlinearAdaptiveMerEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable MER as a trigger for the AUTORUN and RUNTOTARGET modes"
::= { itmex2atvPrecorrector 59 }
itmex2atvPrecorrectorNonlinearAdaptiveLowerShoulderTargetLvl OBJECT-TYPE
SYNTAX Integer32 ( -800 .. 0 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the lower shoulder"
::= { itmex2atvPrecorrector 44 }
itmex2atvPrecorrectorNonlinearAdaptiveLowerShoulderTargetHys OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the lower shoulder"
::= { itmex2atvPrecorrector 16 }
itmex2atvPrecorrectorNonlinearAdaptiveLowerShoulderEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable shoulder level (lower) as a trigger for the AUTORUN and
RUNTOTARGET modes"
::= { itmex2atvPrecorrector 12 }
itmex2atvPrecorrectorNonlinearAdaptiveUpperShoulderTargetLvl OBJECT-TYPE
SYNTAX Integer32 ( -800 .. 0 )
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level for the upper shoulder"
::= { itmex2atvPrecorrector 45 }
itmex2atvPrecorrectorNonlinearAdaptiveUpperShoulderTargetHys OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 1000 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Define a adaptive target level hysteresis for the upper shoulder"
::= { itmex2atvPrecorrector 17 }
itmex2atvPrecorrectorNonlinearAdaptiveUpperShoulderEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable shoulder level (upper) as a trigger for the AUTORUN and
RUNTOTARGET modes"
::= { itmex2atvPrecorrector 13 }
itmex2atvPrecorrectorNonlinearAdaptivePresetNeutralload OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Apply the Neutral spectrum curve"
::= { itmex2atvPrecorrector 90 }
itmex2atvPrecorrectorNonlinearAdaptivePresetFactoryrecall OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Recall the stored Factory spectrum curve from memory"
::= { itmex2atvPrecorrector 91 }
itmex2atvPrecorrectorNonlinearAdaptivePresetFactorystore OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Store current adptive precorrected spectrum as factory curve"
::= { itmex2atvPrecorrector 92 }
itmex2atvPrecorrectorNonlinearAdaptivePresetFactoryclear OBJECT-TYPE
SYNTAX INTEGER { noop(0), activate(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear factory spectrum curve stored in memory to neutral curve"
::= { itmex2atvPrecorrector 93 }
itmex2atvPrecorrectorPaprClipping OBJECT-TYPE
SYNTAX Integer32 ( 200 .. 1200 )
UNITS "0.01 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set the built-in peak clipper function. The value 'max' corresponds
to an unclipped COFDM signal (12dB peak to average ratio).
The value 'min' correspondsto COFDM signal where all peaks >2dB
above average power are clipped. When feeding the output from
the modulator through an amplifier the best overall performance
result is normally obtained if the clipper value used by modulator
clips the signal just a fraction before the amplifier would
clip the signal."
::= { itmex2atvPrecorrector 60 }
itmex2atvPrecorrectorPaprShaping OBJECT-TYPE
SYNTAX Integer32 ( 0 .. 100 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the output peak shaping filter hardness. The value 'min'
correspond to traditional 'hard-clipping' where the clipper
noise is equally distributed below, inside and above the COFDM
spectrum (clipper noise clearly visible in the form of noise
above and below the spectrum. The value 'max' corresponds to
maximum soft clipping where the clipper noise in the sidebands
(above and below the COFDM spectrum) is subjected to maximum
suppression while still maintaining the exact clipper value
(peak-to-average-ration). The suppression of the sideband noise
is obtained as a tradeoff against the in band performance.
The clip filter setting is typically selected as a compromise
between spectrum shoulder performance and in-band signal performance
(MER)."
::= { itmex2atvPrecorrector 61 }
itmex2atvPrecorrectorClipperMode OBJECT-TYPE
SYNTAX INTEGER { monitoring(0), static(1), adaptive(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selection between no, static (manual) and adaptive clipper function"
::= { itmex2atvPrecorrector 74 }
itmex2atvPrecorrectorClipperAdaptive OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clipper shaped by the OptiClipper algorithm"
::= { itmex2atvPrecorrector 75 }
itmex2atvPrecorrectorClipperEnable OBJECT-TYPE
SYNTAX INTEGER { off(0), on(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Clipper enable"
::= { itmex2atvPrecorrector 76 }
itmex2atvPrecorrectorClipperAdaptiveShaping OBJECT-TYPE
SYNTAX Integer32 ( 99 .. 100 )
UNITS "1 %"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Depricated Therefore min and max value are set to 100% Set the
peak shaping filter hardness. The value 'min' correspond to
traditional 'hard-clipping' where the clipper noise is equally
distributed below, inside and above the COFDM spectrum (clipper
noise clearly visible in the form of noise above and below
the spectrum. The value 'max' corresponds to maximum soft clipping
where the clipper noise in the sidebands (above and below the
COFDM spectrum) is subjected to maximum suppression while still
maintaining the exact clipper value (peak-to-average-ration).
The suppression of the sideband noise is obtained as a tradeoff
against the in band performance. The clip filter setting is
typically selected as a compromise between spectrum shoulder
performance and in-band signal performance (MER)."
::= { itmex2atvPrecorrector 81 }
itmex2atvPrecorrectorClipperMonitorStatus OBJECT-TYPE
SYNTAX INTEGER { not-running(0), monitoring(1), initialising(2), initialising-0(3), initialising-10(4), initialising-20(5), initialising-30(6), initialising-40(7), initialising-50(8), initialising-60(9), initialising-70(10), initialising-80(11), initialising-90(12), auto-applying(13), completed(14) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"OptiClipper state"
::= { itmex2atvPrecorrector 64 }
itmex2atvPrecorrectorClipperMonitorShoulderLevelLower OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Lower shoulder level"
::= { itmex2atvPrecorrector 65 }
itmex2atvPrecorrectorClipperMonitorShoulderLevelLowerValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Lower shoulder information valid"
::= { itmex2atvPrecorrector 66 }
itmex2atvPrecorrectorClipperMonitorShoulderLevelUpper OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Upper shoulder level"
::= { itmex2atvPrecorrector 67 }
itmex2atvPrecorrectorClipperMonitorShoulderLevelUpperValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Upper shoulder information valid"
::= { itmex2atvPrecorrector 68 }
itmex2atvPrecorrectorClipperMonitorMer OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MER level"
::= { itmex2atvPrecorrector 69 }
itmex2atvPrecorrectorClipperMonitorMerValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is MER information valid"
::= { itmex2atvPrecorrector 70 }
itmex2atvPrecorrectorClipperMonitorPapr OBJECT-TYPE
SYNTAX Integer32
UNITS "0.1 dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PAPR level"
::= { itmex2atvPrecorrector 71 }
itmex2atvPrecorrectorClipperMonitorPaprValid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is Papr information valid"
::= { itmex2atvPrecorrector 72 }
itmex2atvPrecorrectorClipperMonitorIterations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Iterations performed by the OptiClipper algorithm"
::= { itmex2atvPrecorrector 73 }
itmex2atvPrecorrectorLastTurnAroundTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PrecorrectorLastTurnAroundTime "
::= { itmex2atvPrecorrector 6 }
itmex2atvPrecorrectorSecondsSinceLastUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PrecorrectorSecondsSinceLastUpdate "
::= { itmex2atvPrecorrector 7 }
itmex2atvPrecorrectorLinearLoadNeutral OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorLinearLoadNeutral "
::= { itmex2atvPrecorrector 20 }
itmex2atvPrecorrectorLinearLoadFactory OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorLinearLoadFactory "
::= { itmex2atvPrecorrector 21 }
itmex2atvPrecorrectorLinearUpdateFactoryCurve OBJECT-TYPE
SYNTAX INTEGER { noop(0), update(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorLinearUpdateFactoryCurve "
::= { itmex2atvPrecorrector 25 }
itmex2atvPrecorrectorNonlinearLoadNeutral OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorNonlinearLoadNeutral "
::= { itmex2atvPrecorrector 36 }
itmex2atvPrecorrectorNonlinearLoadFactory OBJECT-TYPE
SYNTAX INTEGER { noop(0), load(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorNonlinearLoadFactory "
::= { itmex2atvPrecorrector 37 }
itmex2atvPrecorrectorNonlinearUpdateFactoryCurve OBJECT-TYPE
SYNTAX INTEGER { noop(0), update(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "PrecorrectorNonlinearUpdateFactoryCurve "
::= { itmex2atvPrecorrector 41 }
--
-- itmex2atv Backplane sub-tree
--
itmex2atvBackplanePolarityHardMute OBJECT-TYPE
SYNTAX INTEGER { activelow(0), activehigh(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the polarity of the Hard Mute input pin on the PTT2 backplane."
::= { itmex2atvBackplane 1 }
itmex2atvBackplanePolarityRFFail OBJECT-TYPE
SYNTAX INTEGER { activelow(0), activehigh(1) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set the polarity of the RF Fail output pin on the PTT2 backplane."
::= { itmex2atvBackplane 2 }
--
-- itmex2atv Notifications sub-tree
--
itmex2atvNotif OBJECT IDENTIFIER ::= { itmex2atvNotifs 0 }
itmex2atvNotifMessage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The current alarm notification message"
::= { itmex2atvNotifs 1 }
itmex2atvNotifState OBJECT-TYPE
SYNTAX INTEGER { off(0), activated(1) }
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The current alarm notification state"
::= { itmex2atvNotifs 2 }
itmex2atvNotifLocalTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The time the current alarm notification state changed"
::= { itmex2atvNotifs 3 }
-- SNMPv2 compliance nonsense --
itmex2atvCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for systems supporting
the this MIB."
MODULE -- this module
MANDATORY-GROUPS {
itmex2atvSystemGroup, itmex2atvInputGroup, itmex2atvOutputGroup,
itmex2atvTestGroup, itmex2atvAlarmGroup, itmex2atvPresetGroup,
itmex2atvEventlogGroup, itmex2atvCommsGroup, itmex2atvPrecorrectorGroup
}
GROUP itmex2atvGpsGroup
DESCRIPTION
"This group is optional."
::= { itmex2atvCompliances 1 }
itmex2atvGroups OBJECT IDENTIFIER ::= { itmex2atvConformance 2 }
itmex2atvSystemGroup OBJECT-GROUP
OBJECTS {
itmex2atvSystemInstrumentFW1Rev,
itmex2atvSystemInstrumentFW1RevBL,
itmex2atvSystemInstrumentFW2Rev,
itmex2atvSystemInstrumentFW2RevBL,
itmex2atvSystemInstrumentFW3Rev,
itmex2atvSystemInstrumentFW4Rev,
itmex2atvSystemInstrumentPCBRev,
itmex2atvSystemInstrumentCalibrationRev,
itmex2atvSystemInstrumentCalibrationDate,
itmex2atvSystemReboot,
itmex2atvSystemRebootDefaultConfig,
itmex2atvSystemDateTime,
itmex2atvSystemImage0Version,
itmex2atvSystemImage0InstalledDate,
itmex2atvSystemImage1version,
itmex2atvSystemImage1InstalledDate,
itmex2atvSystemScheduledActionRecurrence,
itmex2atvSystemScheduledActionHour,
itmex2atvSystemScheduledActionMinute,
itmex2atvSystemScheduledActionWeekday,
itmex2atvSystemScheduledActionMonthDay,
itmex2atvSystemScheduledActionDate,
itmex2atvSystemScheduledActionRandomDelay,
itmex2atvSystemScheduledActionAction,
itmex2atvSystemScheduledActionRepeaterMode,
itmex2atvSystemScheduledActionPresetNo,
itmex2atvSystemScheduledActionRebootImage,
itmex2atvSystemScheduledActionRebootSystemType,
itmex2atvSystemScheduledActionMute,
itmex2atvSystemScheduledActionSWUpgradeProtocol,
itmex2atvSystemScheduledActionSWUpgradeUsername,
itmex2atvSystemScheduledActionSWUpgradePassword,
itmex2atvSystemScheduledActionSWUpgradeImageServer,
itmex2atvSystemScheduledActionSWUpgradeImagePath,
itmex2atvSystemServiceLED
,
itmex2atvSystemLanguage
,
itmex2atvSystemType,
itmex2atvSystemModulationStandard,
itmex2atvSystemCurrentImage,
itmex2atvSystemInstrumentKU,
itmex2atvSystemInstrumentType,
itmex2atvSystemInstrumentOptions,
itmex2atvSystemDateTimeSync,
itmex2atvSystemDateTimeSyncActual,
itmex2atvSystemTimezone,
itmex2atvSystemInstrumentSWRev,
itmex2atvSystemInstrumentBootLoaderRev,
itmex2atvSystemInstrumentKernelRev,
itmex2atvSystemOperationOnTime,
itmex2atvSystemOperationOnAirTime,
itmex2atvSystemOperationNumberOfBoots,
itmex2atvSystemBackplaneid,
itmex2atvSystemBackplaneIdRaw,
itmex2atvSystemBackplaneIdPcb,
itmex2atvSystemBackplaneIdCableOptions,
itmex2atvSystemBackplaneIdMAnuf,
itmex2atvSystemBackplaneCalibrationDate,
itmex2atvSystemBackplaneCalibrationSw,
itmex2atvSystemBackplaneIdPartlist
}
STATUS current
DESCRIPTION
"System group"
::= { itmex2atvGroups 1}
itmex2atvModeGroup OBJECT-GROUP
OBJECTS {
itmex2atvAtvModeStandardVideo,
itmex2atvAtvModeStandardColor,
itmex2atvAtvModeStandardAudioCtrl,
itmex2atvAtvModeStandardAudioStatus,
itmex2atvAtvModeStandardAudioEvent,
itmex2atvAtvModeStandardAudioImpendance,
itmex2atvAtvModeStandardAudioMpx,
itmex2atvAtvModeTeletextline,
itmex2atvAtvModeTeletextThreshold,
itmex2atvAtvModeTeletextEvent,
itmex2atvAtvModecarrierSound1,
itmex2atvAtvModecarrierSound2,
itmex2atvAtvModecarrierSub,
itmex2atvAtvModecarrierVideo,
itmex2atvAtvvideoStatus,
itmex2atvAtvvideoitsline,
itmex2atvAtvvideoWhitelimit,
itmex2atvAtvvideoSynclevel,
itmex2atvAtvvideoResidualCarrier,
itmex2atvAtvvideoAgc,
itmex2atvAtvvideon1ManualGain,
itmex2atvAtvvideon2ManualGain,
itmex2atvAtvvideoGroupDelay,
itmex2atvAtvvideoeventLevellow,
itmex2atvAtvvideoeventLevelhigh,
itmex2atvAtvvideoeventOverload,
itmex2atvAtvvideoeventWhitelimit,
itmex2atvAtvvideoeventitsline,
itmex2atvAtvvideoeventn1Present,
itmex2atvAtvvideoeventn2Present,
itmex2atvAtvvideoSilenceDetector,
itmex2atvAtvvideoSilenceEmitBlanking,
itmex2atvAtvAudioN1Status,
itmex2atvAtvAudioN2Status,
itmex2atvAtvAudioSubcarrierStatus,
itmex2atvAtvAudioCarrierLevelAudio1,
itmex2atvAtvAudioCarrierLevelAudio2,
itmex2atvAtvAudioGainAudio1,
itmex2atvAtvAudioGainAudio2,
itmex2atvAtvAudioGainPilot,
itmex2atvAtvAudiolimiterAudio1,
itmex2atvAtvAudiolimiterAudio2,
itmex2atvAtvAudiopreemphasisn1,
itmex2atvAtvAudiopreemphasisn2,
itmex2atvAtvAudiooverdriveAudio1Event,
itmex2atvAtvAudiooverdriveAudio2Event,
itmex2atvAtvAudiooverdriveSubCarrierEvent,
itmex2atvAtvAudiooverflowAudio1Event,
itmex2atvAtvAudiooverflowAudio2Event,
itmex2atvAtvAudiooverflowSubCarrierEvent,
itmex2atvAtvAudioInputlevelLeft,
itmex2atvAtvAudioInputlevelRight,
itmex2atvAtvAudioInputlevelNicam,
itmex2atvAtvAudioInputlevelSub,
itmex2atvAtvAudioInputlevelMpx,
itmex2atvAtvAudioInputStatusLeft,
itmex2atvAtvAudioInputStatusRight,
itmex2atvAtvAudioInputStatusNicam,
itmex2atvAtvAudioInputStatusSub,
itmex2atvAtvAudioInputStatusMpx,
itmex2atvAtvAudioInputSilenceDetector,
itmex2atvAtvAudioInputSilenceThreshold,
itmex2atvAtvNicamStatus,
itmex2atvAtvNicamCoder,
itmex2atvAtvNicamBackup,
itmex2atvAtvNicamGainn1,
itmex2atvAtvNicamGainn2,
itmex2atvAtvNicampreemphasisn1,
itmex2atvAtvNicampreemphasisn2,
itmex2atvAtvNicamadditionalData,
itmex2atvAtvNicammonosource,
itmex2atvAtvHardwarePcbRevision,
itmex2atvAtvHardwareBomRevision,
itmex2atvAtvInputSwPending,
itmex2atvAtvInputSwSelected,
itmex2atvAtvInputStateinpa,
itmex2atvAtvInputStateinpb,
itmex2atvAtvInputStatesdi1,
itmex2atvAtvInputStatesdi2,
itmex2atvAtvInputStateanl1,
itmex2atvAtvInputStateanl2
}
STATUS current
DESCRIPTION
"ATV Mode group"
::= { itmex2atvGroups 2}
itmex2atvInputGroup OBJECT-GROUP
OBJECTS {
itmex2atvInputASITSPrimarySource,
itmex2atvInputASITSSecondarySource,
itmex2atvInputASIAutoRoutingPolicy,
itmex2atvInputTSPrimaryStatus,
itmex2atvInputTSSecondaryStatus,
itmex2atvInputTSHp,
itmex2atvInputTSLp,
itmex2atvInputEffectiveAutoroutingPolicy,
itmex2atvInputTSHpBitrate,
itmex2atvInputTSLpBitrate,
itmex2atvInputRefOcxoDevType,
itmex2atvInputRefOcxoCalDate,
itmex2atvInputRefOcxoCalVer,
itmex2atvInputRefDirection,
itmex2atvInputRefSource,
itmex2atvInputRefStatus,
itmex2atvInputRef10MhzImpedance,
itmex2atvInputRef10MhzHoldoverDelay,
itmex2atvInputRef10MhzHoldoverForever,
itmex2atvInputRef1PPSImpedance,
itmex2atvInputRef1PPSHoldoverDelay,
itmex2atvInputRef1PPSHoldoverForever,
itmex2atvInputRef1PPSTrigSlope,
itmex2atvInputRef1PPSTrigLevel,
itmex2atvInputASIAutoRoutingDelayHp2Lp,
itmex2atvInputASIAutoRoutingDelayLp2Hp
}
STATUS current
DESCRIPTION
"Input group"
::= { itmex2atvGroups 3}
itmex2atvOutputGroup OBJECT-GROUP
OBJECTS {
itmex2atvOutputMode,
itmex2atvOutputEffectiveLevel,
itmex2atvOutputActualLevel,
itmex2atvOutputPolarity,
itmex2atvOutputRfFrequency,
itmex2atvOutputRfFrequencyOffset,
itmex2atvOutputRfLevel,
itmex2atvOutputRfCableMode,
itmex2atvOutputRfCableConstantLevelOffset,
itmex2atvOutputRfCableFrequencyLevelOffset0,
itmex2atvOutputRfCableFrequencyLevelOffset1,
itmex2atvOutputRfCableFrequencyLevelOffset2,
itmex2atvOutputRfCableFrequencyLevelOffset3,
itmex2atvOutputRfCableFrequencyLevelOffset4,
itmex2atvOutputRfCableFrequencyLevelOffset5,
itmex2atvOutputRfDetectedActualLevel,
itmex2atvOutputRfDetectedLowerLevelLimit,
itmex2atvOutputRfDetectedLowerLevelcontrol,
itmex2atvOutputRfDetectedHigherLevelLimit,
itmex2atvOutputRfDetectedHigherLevelcontrol,
itmex2atvOutputRfAlcControl,
itmex2atvOutputRfAlcSense,
itmex2atvOutputRfAlcSetpointPort1,
itmex2atvOutputRfAlcSetpointPort2,
itmex2atvOutputRfAlcMarkSetpoint1,
itmex2atvOutputRfAlcMarkSetpoint2,
itmex2atvOutputRfAlcStatus,
itmex2atvOutputRfAlcStatusInformation,
itmex2atvOutputMute,
itmex2atvOutputMuteReason,
itmex2atvOutputHpaStatus1Text,
itmex2atvOutputHpaStatus2Text,
itmex2atvOutputHpaStatus3Text,
itmex2atvOutputHpaStatus4Text,
itmex2atvOutputHpaStatus5Text,
itmex2atvOutputHpaStatus6Text,
itmex2atvOutputHpaStatus7Text,
itmex2atvOutputHpaStatus8Text,
itmex2atvOutputHpaStatus9Text,
itmex2atvOutputHpaStatus10Text,
itmex2atvOutputHpaStatus11Text,
itmex2atvOutputHpaStatus12Text,
itmex2atvOutputHpaStatus1Param,
itmex2atvOutputHpaStatus2Param,
itmex2atvOutputHpaStatus3Param,
itmex2atvOutputHpaStatus4Param,
itmex2atvOutputHpaStatus5Param,
itmex2atvOutputHpaStatus6Param,
itmex2atvOutputHpaStatus7Param,
itmex2atvOutputHpaStatus8Param,
itmex2atvOutputHpaStatus9Param,
itmex2atvOutputHpaStatus10Param,
itmex2atvOutputHpaStatus11Param,
itmex2atvOutputHpaStatus12Param,
itmex2atvOutputHpaAlarm1Text,
itmex2atvOutputHpaAlarm2Text,
itmex2atvOutputHpaAlarm3Text,
itmex2atvOutputHpaAlarm4Text,
itmex2atvOutputHpaAlarm5Text,
itmex2atvOutputHpaAlarm6Text,
itmex2atvOutputHpaAlarm7Text,
itmex2atvOutputHpaAlarm8Text,
itmex2atvOutputHpaAlarm9Text,
itmex2atvOutputHpaAlarm10Text,
itmex2atvOutputHpaAlarm11Text,
itmex2atvOutputHpaAlarm12Text,
itmex2atvOutputHpaAlarm1Status,
itmex2atvOutputHpaAlarm2Status,
itmex2atvOutputHpaAlarm3Status,
itmex2atvOutputHpaAlarm4Status,
itmex2atvOutputHpaAlarm5Status,
itmex2atvOutputHpaAlarm6Status,
itmex2atvOutputHpaAlarm7Status,
itmex2atvOutputHpaAlarm8Status,
itmex2atvOutputHpaAlarm9Status,
itmex2atvOutputHpaAlarm10Status,
itmex2atvOutputHpaAlarm11Status,
itmex2atvOutputHpaAlarm12Status,
itmex2atvOutputHpaPowerForward,
itmex2atvOutputHpaPowerReflected,
itmex2atvOutputHpaPowerHeatsinkTemp
,itmex2atvOutputBandwidth,
itmex2atvOutputChannel,
itmex2atvOutputSynchronized,
itmex2atvOutputMute,
itmex2atvOutputPowerLevel
}
STATUS current
DESCRIPTION
"Output group"
::= { itmex2atvGroups 4}
itmex2atvGpsGroup OBJECT-GROUP
OBJECTS {
itmex2atvGpsInUse,
itmex2atvGpsMaintenance,
itmex2atvGpsBias,
itmex2atvGpsbiasVoltage
,
itmex2atvGpsCableDelay
,
itmex2atvGpsHoldoverForever,
itmex2atvGpsHoldoverTime,
itmex2atvGpsSatelliteSystemGPS,
itmex2atvGpsSatelliteSystemGLONASS,
itmex2atvGpsSatelliteSystemGALILEO,
itmex2atvGpsSatelliteSystemCOMPASS,
itmex2atvGpsVersion,
itmex2atvGps1PPSStatus,
itmex2atvGpsTime,
itmex2atvGpsState,
itmex2atvGpsVisibleSatellitesSnr,
itmex2atvGpsTrackedSatellitesSnr,
itmex2atvGpsVisibleSatellites,
itmex2atvGpsTrackedSatellites,
itmex2atvGpsLongtitude,
itmex2atvGpsLatitude,
itmex2atvGpsAltitude
}
STATUS current
DESCRIPTION
"GPS group"
::= { itmex2atvGroups 7}
itmex2atvTestGroup OBJECT-GROUP
OBJECTS {
itmex2atvTestEnable,
itmex2atvTestEnableReconnect,
itmex2atvTestscarrierFrequencyOffset,
itmex2atvTestColorBurst
}
STATUS current
DESCRIPTION
"Test Signal group"
::= { itmex2atvGroups 13}
itmex2atvAlarmGroup OBJECT-GROUP
OBJECTS {
itmex2atvGroupAlarmDescription,
itmex2atvGroupAlarmState,
itmex2atvGroupAlarmActionEventlog,
itmex2atvGroupAlarmActionRelay1,
itmex2atvGroupAlarmActionRelay2,
itmex2atvGroupAlarmActionTrap,
itmex2atvGroupAlarmActionEmail,
itmex2atvGroupAlarmActionAlarmLED,
itmex2atvGroupAlarmActionForceMode,
itmex2atvPrimaryAlarmDescription,
itmex2atvPrimaryAlarmState,
itmex2atvPrimaryAlarmActionEventlog,
itmex2atvPrimaryAlarmActionRelay1,
itmex2atvPrimaryAlarmActionRelay2,
itmex2atvPrimaryAlarmActionTrap,
itmex2atvPrimaryAlarmActionEmail,
itmex2atvPrimaryAlarmActionAlarmLED,
itmex2atvPrimaryAlarmActionForceMode,
itmex2atvSecondaryAlarmDescription,
itmex2atvSecondaryAlarmState,
itmex2atvSecondaryAlarmActionEventlog,
itmex2atvSecondaryAlarmActionRelay1,
itmex2atvSecondaryAlarmActionRelay2,
itmex2atvSecondaryAlarmActionTrap,
itmex2atvSecondaryAlarmActionEmail,
itmex2atvSecondaryAlarmActionAlarmLED,
itmex2atvSecondaryAlarmActionForceMode,
itmex2atvSFNAlarmDescription,
itmex2atvSFNAlarmState,
itmex2atvSFNAlarmActionEventlog,
itmex2atvSFNAlarmActionRelay1,
itmex2atvSFNAlarmActionRelay2,
itmex2atvSFNAlarmActionTrap,
itmex2atvSFNAlarmActionEmail,
itmex2atvSFNAlarmActionAlarmLED,
itmex2atvSFNAlarmActionForceMode,
itmex2atvReferenceAlarmDescription,
itmex2atvReferenceAlarmState,
itmex2atvReferenceAlarmActionEventlog,
itmex2atvReferenceAlarmActionRelay1,
itmex2atvReferenceAlarmActionRelay2,
itmex2atvReferenceAlarmActionTrap,
itmex2atvReferenceAlarmActionEmail,
itmex2atvReferenceAlarmActionAlarmLED,
itmex2atvReferenceAlarmActionForceMode,
itmex2atvRFAlarmDescription,
itmex2atvRFAlarmState,
itmex2atvRFAlarmActionEventlog,
itmex2atvRFAlarmActionRelay1,
itmex2atvRFAlarmActionRelay2,
itmex2atvRFAlarmActionTrap,
itmex2atvRFAlarmActionEmail,
itmex2atvRFAlarmActionAlarmLED,
itmex2atvRFAlarmActionForceMode,
itmex2atvGPSAlarmDescription,
itmex2atvGPSAlarmState,
itmex2atvGPSAlarmActionEventlog,
itmex2atvGPSAlarmActionRelay1,
itmex2atvGPSAlarmActionRelay2,
itmex2atvGPSAlarmActionTrap,
itmex2atvGPSAlarmActionEmail,
itmex2atvGPSAlarmActionAlarmLED,
itmex2atvGPSAlarmActionForceMode,
itmex2atvExternalAlarmDescription,
itmex2atvExternalAlarmState,
itmex2atvExternalAlarmActionEventlog,
itmex2atvExternalAlarmActionRelay1,
itmex2atvExternalAlarmActionRelay2,
itmex2atvExternalAlarmActionTrap,
itmex2atvExternalAlarmActionEmail,
itmex2atvExternalAlarmActionAlarmLED,
itmex2atvExternalAlarmActionForceMode,
itmex2atvHWMonitorAlarmDescription,
itmex2atvHWMonitorAlarmState,
itmex2atvHWMonitorAlarmActionEventlog,
itmex2atvHWMonitorAlarmActionRelay1,
itmex2atvHWMonitorAlarmActionRelay2,
itmex2atvHWMonitorAlarmActionTrap,
itmex2atvHWMonitorAlarmActionEmail,
itmex2atvHWMonitorAlarmActionAlarmLED,
itmex2atvHWMonitorAlarmActionForceMode,
itmex2atvCommsAlarmDescription,
itmex2atvCommsAlarmState,
itmex2atvCommsAlarmActionEventlog,
itmex2atvCommsAlarmActionRelay1,
itmex2atvCommsAlarmActionRelay2,
itmex2atvCommsAlarmActionTrap,
itmex2atvCommsAlarmActionEmail,
itmex2atvCommsAlarmActionAlarmLED,
itmex2atvCommsAlarmActionForceMode,
itmex2atvInternalAlarmDescription,
itmex2atvInternalAlarmState,
itmex2atvInternalAlarmActionEventlog,
itmex2atvInternalAlarmActionRelay1,
itmex2atvInternalAlarmActionRelay2,
itmex2atvInternalAlarmActionTrap,
itmex2atvInternalAlarmActionEmail,
itmex2atvInternalAlarmActionAlarmLED,
itmex2atvInternalAlarmActionForceMode
}
STATUS current
DESCRIPTION
"Alarm group"
::= { itmex2atvGroups 14}
itmex2atvPresetGroup OBJECT-GROUP
OBJECTS {
itmex2atvPresetName,
itmex2atvPresetRecall,
itmex2atvPresetStore,
itmex2atvPresetLastRecalled
}
STATUS current
DESCRIPTION
"Preset group"
::= { itmex2atvGroups 15}
itmex2atvEventlogGroup OBJECT-GROUP
OBJECTS {
itmex2atvEventlogID,
itmex2atvEventlogTimestamp,
itmex2atvEventlogText,
itmex2atvEventlogClear,
itmex2atvEventlogEnable,
itmex2atvEventlogMode
}
STATUS current
DESCRIPTION
"Eventlog group"
::= { itmex2atvGroups 16}
itmex2atvCommsGroup OBJECT-GROUP
OBJECTS {
itmex2atvCommsAccessPasswordObserver,
itmex2atvCommsAccessPasswordOperator,
itmex2atvCommsAccessPasswordAdministrator,
itmex2atvCommsStaticRouteType,
itmex2atvCommsStaticRoutePrefix,
itmex2atvCommsStaticRoutePrefixSize,
itmex2atvCommsStaticRouteTarget,
itmex2atvCommsStaticRoutePhysicalInterface,
itmex2atvCommsAlarmEmailReceiver,
itmex2atvCommsNetworkWarnings,
itmex2atvCommsSeparatedSwitchPorts,
itmex2atvCommsBroadcastStormProtection,
itmex2atvCommsLocalPhysicalInterface,
itmex2atvCommsLocalDhcpMode,
itmex2atvCommsLocalStaticIpAddr,
itmex2atvCommsLocalStaticNetmask,
itmex2atvCommsLocalVlanEnable,
itmex2atvCommsLocalVlanId,
itmex2atvCommsLocalServiceSNMP,
itmex2atvCommsLocalServiceSCPI,
itmex2atvCommsLocalServiceTSoIP,
itmex2atvCommsLocalServiceRIP,
itmex2atvCommsLocalCurrentIpAddr,
itmex2atvCommsLocalCurrentNetmask,
itmex2atvCommsRemoteEnable,
itmex2atvCommsRemotePhysicalInterface,
itmex2atvCommsRemoteDhcpMode,
itmex2atvCommsRemoteStaticIpAddr,
itmex2atvCommsRemoteStaticNetmask,
itmex2atvCommsRemoteVlanEnable,
itmex2atvCommsRemoteVlanId,
itmex2atvCommsRemoteServiceSNMP,
itmex2atvCommsRemoteServiceSCPI,
itmex2atvCommsRemoteServiceTSoIP,
itmex2atvCommsRemoteServiceWeb,
itmex2atvCommsRemoteServiceRIP,
itmex2atvCommsRemoteCurrentIpAddr,
itmex2atvCommsRemoteCurrentNetmask,
itmex2atvCommsGbeAdminEnable,
itmex2atvCommsGbeAdminPhysicalInterface,
itmex2atvCommsGbeAdminDhcpMode,
itmex2atvCommsGbeAdminStaticIpAddr,
itmex2atvCommsGbeAdminStaticNetmask,
itmex2atvCommsGbeAdminVlanEnable,
itmex2atvCommsGbeAdminVlanId,
itmex2atvCommsGbeAdminServiceSNMP,
itmex2atvCommsGbeAdminServiceSCPI,
itmex2atvCommsGbeAdminServiceTSoIP,
itmex2atvCommsGbeAdminServiceWeb,
itmex2atvCommsGbeAdminServiceRIP,
itmex2atvCommsGbeAdminCurrentIpAddr,
itmex2atvCommsGbeAdminCurrentNetmask,
itmex2atvCommsBackupEnable,
itmex2atvCommsBackupPhysicalInterface,
itmex2atvCommsBackupDhcpMode,
itmex2atvCommsBackupStaticIpAddr,
itmex2atvCommsBackupStaticNetmask,
itmex2atvCommsBackupVlanEnable,
itmex2atvCommsBackupVlanId,
itmex2atvCommsBackupServiceSNMP,
itmex2atvCommsBackupServiceSCPI,
itmex2atvCommsBackupServiceTSoIP,
itmex2atvCommsBackupServiceWeb,
itmex2atvCommsBackupServiceRIP,
itmex2atvCommsBackupCurrentIpAddr,
itmex2atvCommsBackupCurrentNetmask,
itmex2atvCommsPortEnable,
itmex2atvCommsPortPhysicalInterface,
itmex2atvCommsPortDhcpMode,
itmex2atvCommsPortStaticIpAddr,
itmex2atvCommsPortStaticNetmask,
itmex2atvCommsPortVlanEnable,
itmex2atvCommsPortVlanId,
itmex2atvCommsPortServiceSNMP,
itmex2atvCommsPortServiceSCPI,
itmex2atvCommsPortServiceTSoIP,
itmex2atvCommsPortServiceWeb,
itmex2atvCommsPortServiceRIP,
itmex2atvCommsPortCurrentIpAddr,
itmex2atvCommsPortCurrentNetmask,
itmex2atvCommsSNMPServicePort,
itmex2atvCommsSNMPReadOnlyCommunity,
itmex2atvCommsSNMPReadWriteCommunity,
itmex2atvCommsSNMPTrapCommunity,
itmex2atvCommsSNMPTrapDestination,
itmex2atvCommsSNMPTrapDestination2,
itmex2atvCommsSNMPTrapDestination3,
itmex2atvCommsSNMPTrapDestination4,
itmex2atvCommsSNMPTrapDestination5,
itmex2atvCommsSNMPTrapDestinationPort,
itmex2atvCommsSNMPTrapDestinationPort2,
itmex2atvCommsSNMPTrapDestinationPort3,
itmex2atvCommsSNMPTrapDestinationPort4,
itmex2atvCommsSNMPTrapDestinationPort5,
itmex2atvCommsStaticGateway,
itmex2atvCommsCurrentGateway,
itmex2atvCommsStaticHostname,
itmex2atvCommsCurrentHostname,
itmex2atvCommsStaticDNSDomain,
itmex2atvCommsCurrentDNSDomain,
itmex2atvCommsStaticDNS1ServerAddress,
itmex2atvCommsStaticDNS2ServerAddress,
itmex2atvCommsStaticDNS3ServerAddress,
itmex2atvCommsCurrentDNS1ServerAddress,
itmex2atvCommsCurrentDNS2ServerAddress,
itmex2atvCommsCurrentDNS3ServerAddress,
itmex2atvCommsStaticNtpServerAddress,
itmex2atvCommsStaticNtp2ServerAddress,
itmex2atvCommsStaticNtp3ServerAddress,
itmex2atvCommsCurrentNtpServerAddress,
itmex2atvCommsCurrentNtp2ServerAddress,
itmex2atvCommsCurrentNtp3ServerAddress,
itmex2atvCommsEmailServerAddress,
itmex2atvCommsSecureWebPort,
itmex2atvCommsWebProto,
itmex2atvCommsWebServicePort,
itmex2atvCommsSCPIServicePort,
itmex2atvCommsSCPIServerBaudrate,
itmex2atvCommsSCPIUartInterface,
itmex2atvCommsRipPort,
itmex2atvCommsIGMPVersion,
itmex2atvCommsIGMPQueryRobustnessCount,
itmex2atvCommsIGMPv3UnsolicitedReportInterval,
itmex2atvCommsIGMPv2UnsolicitedReportInterval,
itmex2atvCommsAccessAllowed,
itmex2atvCommsAccessAllowedTimeout,
itmex2atvCommsAccessAllowedTimeLeft,
itmex2atvCommsNtpStatusMessage,
itmex2atvCommsNtpStatusLeapsec,
itmex2atvCommsNtpStatusSource,
itmex2atvCommsNtpPeerRmsJitter,
itmex2atvCommsNtpPeerClockOffset,
itmex2atvCommsNtpPeerRoundtripDelay,
itmex2atvCommsNtpPeerDispertion,
itmex2atvCommsNtpLoopRmsJitter,
itmex2atvCommsNtpLoopClockOffset,
itmex2atvCommsNtpLoopRmsWander,
itmex2atvCommsNtpLoopFreqOff
}
STATUS current
DESCRIPTION
"Data network communications group"
::= { itmex2atvGroups 17}
itmex2atvPrecorrectorGroup OBJECT-GROUP
OBJECTS {
itmex2atvPrecorrectorLastTurnAroundTime,
itmex2atvPrecorrectorSecondsSinceLastUpdate,
itmex2atvPrecorrectorLinearLoadNeutral,
itmex2atvPrecorrectorLinearLoadFactory,
itmex2atvPrecorrectorLinearUpdateFactoryCurve,
itmex2atvPrecorrectorNonlinearLoadNeutral,
itmex2atvPrecorrectorNonlinearLoadFactory,
itmex2atvPrecorrectorNonlinearUpdateFactoryCurve,
itmex2atvPrecorrectorVersionadaptive,
itmex2atvPrecorrectorVersionoptipower,
itmex2atvPrecorrectorHeadroom,
itmex2atvPrecorrectorLinearAdaptive,
itmex2atvPrecorrectorLinearMode,
itmex2atvPrecorrectorLinearSenseEnable,
itmex2atvPrecorrectorLinearMonitorStatus,
itmex2atvPrecorrectorLinearMonitorSenseLevel,
itmex2atvPrecorrectorLinearMonitorSenseValid,
itmex2atvPrecorrectorLinearMonitorSenseBadCount,
itmex2atvPrecorrectorLinearMonitorAmplitudeRipple,
itmex2atvPrecorrectorLinearMonitorAmplitudeRippleValid,
itmex2atvPrecorrectorLinearMonitorGroupDelay,
itmex2atvPrecorrectorLinearMonitorGroupDelayValid,
itmex2atvPrecorrectorLinearMonitorDiscartedIterations,
itmex2atvPrecorrectorLinearMonitorIterations,
itmex2atvPrecorrectorLinearAdapMode,
itmex2atvPrecorrectorLinearAdapAmplitudeRippleTargetLevel,
itmex2atvPrecorrectorLinearAdapAmplitudeRippleTargetHys,
itmex2atvPrecorrectorLinearAdapAmplitudeRippleEnable,
itmex2atvPrecorrectorLinearAdapGroupDelayTargetLevel,
itmex2atvPrecorrectorLinearAdapGroupDelayTargetHys,
itmex2atvPrecorrectorLinearAdapGroupDelayEnable,
itmex2atvPrecorrectorLinearAdapPresetNeutralload,
itmex2atvPrecorrectorLinearAdapPresetFactoryrecall,
itmex2atvPrecorrectorLinearAdapPresetFactorystore,
itmex2atvPrecorrectorLinearAdapPresetFactoryclear,
itmex2atvPrecorrectorLinearAttenuation,
itmex2atvPrecorrectorNonlinearAdaptive,
itmex2atvPrecorrectorNonlinearMode,
itmex2atvPrecorrectorNonlinearSenseEnable,
itmex2atvPrecorrectorNonlinearMonitorStatus,
itmex2atvPrecorrectorNonlinearMonitorSenseLevel,
itmex2atvPrecorrectorNonlinearMonitorSenseValid,
itmex2atvPrecorrectorNonlinearMonitorSenseBadCount,
itmex2atvPrecorrectorNonlinearMonitorLowerShoulderLevel,
itmex2atvPrecorrectorNonlinearMonitorLowerShoulderValid,
itmex2atvPrecorrectorNonlinearMonitorUpperShoulderLevel,
itmex2atvPrecorrectorNonlinearMonitorUpperShoulderValid,
itmex2atvPrecorrectorNonlinearMonitorDiscartedIterations,
itmex2atvPrecorrectorNonlinearMonitorIterations,
itmex2atvPrecorrectorNonlinearMonitorMer,
itmex2atvPrecorrectorNonlinearMonitorMerValid,
itmex2atvPrecorrectorNonlinearMonitorPapr,
itmex2atvPrecorrectorNonlinearMonitorPaprValid,
itmex2atvPrecorrectorNonlinearAttenuation,
itmex2atvPrecorrectorNonlinearAdaptiveMode,
itmex2atvPrecorrectorNonlinearAdaptiveMaxRfPaprEnable,
itmex2atvPrecorrectorNonlinearAdaptiveMaxRfPaprLimit,
itmex2atvPrecorrectorNonlinearAdaptiveMerTarget,
itmex2atvPrecorrectorNonlinearAdaptiveMerTargetHys,
itmex2atvPrecorrectorNonlinearAdaptiveMerEnable,
itmex2atvPrecorrectorNonlinearAdaptiveLowerShoulderTargetLvl,
itmex2atvPrecorrectorNonlinearAdaptiveLowerShoulderTargetHys,
itmex2atvPrecorrectorNonlinearAdaptiveLowerShoulderEnable,
itmex2atvPrecorrectorNonlinearAdaptiveUpperShoulderTargetLvl,
itmex2atvPrecorrectorNonlinearAdaptiveUpperShoulderTargetHys,
itmex2atvPrecorrectorNonlinearAdaptiveUpperShoulderEnable,
itmex2atvPrecorrectorNonlinearAdaptivePresetNeutralload,
itmex2atvPrecorrectorNonlinearAdaptivePresetFactoryrecall,
itmex2atvPrecorrectorNonlinearAdaptivePresetFactorystore,
itmex2atvPrecorrectorNonlinearAdaptivePresetFactoryclear,
itmex2atvPrecorrectorPaprClipping,
itmex2atvPrecorrectorPaprShaping,
itmex2atvPrecorrectorClipperMode,
itmex2atvPrecorrectorClipperAdaptive,
itmex2atvPrecorrectorClipperEnable,
itmex2atvPrecorrectorClipperAdaptiveShaping,
itmex2atvPrecorrectorClipperMonitorStatus,
itmex2atvPrecorrectorClipperMonitorShoulderLevelLower,
itmex2atvPrecorrectorClipperMonitorShoulderLevelLowerValid,
itmex2atvPrecorrectorClipperMonitorShoulderLevelUpper,
itmex2atvPrecorrectorClipperMonitorShoulderLevelUpperValid,
itmex2atvPrecorrectorClipperMonitorMer,
itmex2atvPrecorrectorClipperMonitorMerValid,
itmex2atvPrecorrectorClipperMonitorPapr,
itmex2atvPrecorrectorClipperMonitorPaprValid,
itmex2atvPrecorrectorClipperMonitorIterations
}
STATUS current
DESCRIPTION
"Precorrector group"
::= { itmex2atvGroups 25}
itmex2atvBackplaneGroup OBJECT-GROUP
OBJECTS {
itmex2atvBackplanePolarityHardMute,
itmex2atvBackplanePolarityRFFail
}
STATUS current
DESCRIPTION
"Backplane group"
::= { itmex2atvGroups 27}
itmex2atvNotifsGroup OBJECT-GROUP
OBJECTS {
itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime
}
STATUS current
DESCRIPTION
"Notification objects group"
::= { itmex2atvGroups 64 }
--
-- Agent Capability
--
itmex2atvAgent AGENT-CAPABILITIES
PRODUCT-RELEASE "SWITELCOATV_P3_1_02_358 build 1615718558"
STATUS current
DESCRIPTION "Itelco MEX2 ATV Modulator agent"
SUPPORTS ITMEX2ATV-MIB
INCLUDES {
itmex2atvSystemGroup,
itmex2atvGpsGroup,
itmex2atvTestGroup,
itmex2atvPresetGroup,
itmex2atvEventlogGroup,
itmex2atvCommsGroup,
itmex2atvBackplaneGroup,
itmex2atvAlarmGroup
}
::= { itmex2atvConformance 3 }
--
-- System Notifications (aka Traps)
--
itmex2atvNotificationsGroups OBJECT IDENTIFIER ::= { itmex2atvConformance 4 }
itmex2atvNotifModulatorAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Modulator Alarms"
::= { itmex2atvNotif 3 }
itmex2atvNotifTSPrimaryAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ASI TS Primary Alarms"
::= { itmex2atvNotif 5 }
itmex2atvNotifTSSecondaryAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ASI TS Secondary Alarms"
::= { itmex2atvNotif 6 }
itmex2atvNotifSFNAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"SFN Alarms"
::= { itmex2atvNotif 7 }
itmex2atvNotifRefenceClockAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Reference Alarms"
::= { itmex2atvNotif 8 }
itmex2atvNotifRFAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"RF Alarms"
::= { itmex2atvNotif 9 }
itmex2atvNotifGNSSAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Alarms"
::= { itmex2atvNotif 10 }
itmex2atvNotifTSoIPAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"TSoIP Alarms"
::= { itmex2atvNotif 12 }
itmex2atvNotifExternalAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"External Alarms"
::= { itmex2atvNotif 13 }
itmex2atvNotifHWMonitorAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"HW Monitor Alarms"
::= { itmex2atvNotif 14 }
itmex2atvNotifCommAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Communications Alarms"
::= { itmex2atvNotif 15 }
itmex2atvNotifASIAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ASI Alarms"
::= { itmex2atvNotif 16 }
itmex2atvNotifInternalAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Internal Alarms"
::= { itmex2atvNotif 18 }
itmex2atvNotifTSPrimarySyncLossAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"TS Primary Sync Loss"
::= { itmex2atvNotif 21 }
itmex2atvNotifTSSecondarySyncLossAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"TS Secondary Sync Loss"
::= { itmex2atvNotif 32 }
itmex2atvNotifRFOverloadProtectionAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Overload Protection"
::= { itmex2atvNotif 44 }
itmex2atvNotifCommeth0Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ETH0 Conn. State"
::= { itmex2atvNotif 55 }
itmex2atvNotifCommeth1Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ETH1 Conn. State"
::= { itmex2atvNotif 56 }
itmex2atvNotifCommeth2Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ETH2 Conn. State"
::= { itmex2atvNotif 57 }
itmex2atvNotifCommeth3Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ETH3 Conn. State"
::= { itmex2atvNotif 58 }
itmex2atvNotifCommeth4Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ETH4 Conn. State"
::= { itmex2atvNotif 59 }
itmex2atvNotifExternalHpa-refAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"HPA Reflected"
::= { itmex2atvNotif 72 }
itmex2atvNotifExternalHpa-absAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"HPA RF ABSENT"
::= { itmex2atvNotif 73 }
itmex2atvNotifExternalHpa-warnAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"HPA Warning"
::= { itmex2atvNotif 74 }
itmex2atvNotifExternalHpa-faultAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"HPA Fault"
::= { itmex2atvNotif 75 }
itmex2atvNotifRefenceClockExtern1PPSLossAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 1PPS Loss"
::= { itmex2atvNotif 76 }
itmex2atvNotifRefenceClockIntern1PPSLossAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Int. 10MHz Loss"
::= { itmex2atvNotif 77 }
itmex2atvNotifRefenceClockExtern10MHzLossAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 10MHz Loss"
::= { itmex2atvNotif 78 }
itmex2atvNotifRFAlcRangeAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"ALC Range"
::= { itmex2atvNotif 79 }
itmex2atvNotifRFLevelOutOfRangeAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"RF Level Out of Range"
::= { itmex2atvNotif 87 }
itmex2atvNotifRefenceClockNTPSyncLossAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"NTP Sync Loss"
::= { itmex2atvNotif 89 }
itmex2atvNotifGNSSUnlockedAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Unlocked"
::= { itmex2atvNotif 98 }
itmex2atvNotifGNSSAntennaFaultAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Antenna Fault"
::= { itmex2atvNotif 107 }
itmex2atvNotifGNSSHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Holdover"
::= { itmex2atvNotif 108 }
itmex2atvNotifRefenceClockExternal10MHzHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 10MHz Ref Holdover"
::= { itmex2atvNotif 109 }
itmex2atvNotifRefenceClockExternal1PPSHoldOverAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Ext. 1PPS Ref Holdover"
::= { itmex2atvNotif 110 }
itmex2atvNotifInternalBackplaneAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Backplane Status"
::= { itmex2atvNotif 129 }
itmex2atvNotifInternalReferenceClockAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Reference Status"
::= { itmex2atvNotif 132 }
itmex2atvNotifInternalUpConverterAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Upconverter Status"
::= { itmex2atvNotif 134 }
itmex2atvNotifInternalDownConverterAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Downconverter Status"
::= { itmex2atvNotif 135 }
itmex2atvNotifInternalMainboardAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Main board Status"
::= { itmex2atvNotif 136 }
itmex2atvNotifInternalBatteryAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Main Board Battery"
::= { itmex2atvNotif 137 }
itmex2atvNotifInternalFirmware1Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Firmware 1 Status"
::= { itmex2atvNotif 139 }
itmex2atvNotifInternalGNSSAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"GNSS Status"
::= { itmex2atvNotif 142 }
itmex2atvNotifInternalSatelliteAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Satrecv Status"
::= { itmex2atvNotif 143 }
itmex2atvNotifInternalEthAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"EtherNet Port Failure"
::= { itmex2atvNotif 146 }
itmex2atvNotifHWMonitorFPGAAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Main Board FPGA Temperature"
::= { itmex2atvNotif 156 }
itmex2atvNotifHWMonitorMainBoardCPUTemperatureAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Main Board CPU Temperature"
::= { itmex2atvNotif 157 }
itmex2atvNotifHWMonitorMainBoardTemperatureAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Main Board Temperature"
::= { itmex2atvNotif 158 }
itmex2atvNotifHWMonitorLeftFanAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Left Chassis Fan"
::= { itmex2atvNotif 159 }
itmex2atvNotifHWMonitorRightFan2Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Right Chassis Fan"
::= { itmex2atvNotif 160 }
itmex2atvNotifHWMonitorBackplaneTemperatureAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Backplane Temperature"
::= { itmex2atvNotif 162 }
itmex2atvNotifInternalPLLUnlockedAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"PLL Out of Lock"
::= { itmex2atvNotif 182 }
itmex2atvNotifExternalInput5Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 5"
::= { itmex2atvNotif 183 }
itmex2atvNotifExternalInput6Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 6"
::= { itmex2atvNotif 186 }
itmex2atvNotifExternalInput7Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 7"
::= { itmex2atvNotif 187 }
itmex2atvNotifExternalInput8Alarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Alarm Input 8"
::= { itmex2atvNotif 188 }
itmex2atvNotifInternalCalibrationAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Calibration Data"
::= { itmex2atvNotif 198 }
itmex2atvNotifCommnetconfAlarm NOTIFICATION-TYPE
OBJECTS { itmex2atvNotifMessage, itmex2atvNotifState, itmex2atvNotifLocalTime }
STATUS current
DESCRIPTION
"Network Configuration"
::= { itmex2atvNotif 199 }
itmex2atvNotifGroupModulatorAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifModulatorAlarm
}
STATUS current
DESCRIPTION
"Modulator Alarms"
::= { itmex2atvNotificationsGroups 3 }
itmex2atvNotifGroupTSPrimaryAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifTSPrimaryAlarm,
itmex2atvNotifTSPrimarySyncLossAlarm
}
STATUS current
DESCRIPTION
"ASI TS Primary Alarms"
::= { itmex2atvNotificationsGroups 5 }
itmex2atvNotifGroupTSSecondaryAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifTSSecondaryAlarm,
itmex2atvNotifTSSecondarySyncLossAlarm
}
STATUS current
DESCRIPTION
"ASI TS Secondary Alarms"
::= { itmex2atvNotificationsGroups 6 }
itmex2atvNotifGroupSFNAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifSFNAlarm
}
STATUS current
DESCRIPTION
"SFN Alarms"
::= { itmex2atvNotificationsGroups 7 }
itmex2atvNotifGroupRefenceClockAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifRefenceClockAlarm,
itmex2atvNotifRefenceClockExtern1PPSLossAlarm,
itmex2atvNotifRefenceClockIntern1PPSLossAlarm,
itmex2atvNotifRefenceClockExtern10MHzLossAlarm,
itmex2atvNotifRefenceClockNTPSyncLossAlarm,
itmex2atvNotifRefenceClockExternal10MHzHoldOverAlarm,
itmex2atvNotifRefenceClockExternal1PPSHoldOverAlarm
}
STATUS current
DESCRIPTION
"Reference Alarms"
::= { itmex2atvNotificationsGroups 8 }
itmex2atvNotifGroupRFAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifRFAlarm,
itmex2atvNotifRFOverloadProtectionAlarm,
itmex2atvNotifRFAlcRangeAlarm,
itmex2atvNotifRFLevelOutOfRangeAlarm
}
STATUS current
DESCRIPTION
"RF Alarms"
::= { itmex2atvNotificationsGroups 9 }
itmex2atvNotifGroupGNSSAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifGNSSAlarm,
itmex2atvNotifGNSSUnlockedAlarm,
itmex2atvNotifGNSSAntennaFaultAlarm,
itmex2atvNotifGNSSHoldOverAlarm
}
STATUS current
DESCRIPTION
"GNSS Alarms"
::= { itmex2atvNotificationsGroups 10 }
itmex2atvNotifGroupTSoIPAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifTSoIPAlarm
}
STATUS current
DESCRIPTION
"TSoIP Alarms"
::= { itmex2atvNotificationsGroups 12 }
itmex2atvNotifGroupExternalAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifExternalAlarm,
itmex2atvNotifExternalHpa-refAlarm,
itmex2atvNotifExternalHpa-absAlarm,
itmex2atvNotifExternalHpa-warnAlarm,
itmex2atvNotifExternalHpa-faultAlarm,
itmex2atvNotifExternalInput5Alarm,
itmex2atvNotifExternalInput6Alarm,
itmex2atvNotifExternalInput7Alarm,
itmex2atvNotifExternalInput8Alarm
}
STATUS current
DESCRIPTION
"External Alarms"
::= { itmex2atvNotificationsGroups 13 }
itmex2atvNotifGroupHWMonitorAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifHWMonitorAlarm,
itmex2atvNotifHWMonitorFPGAAlarm,
itmex2atvNotifHWMonitorMainBoardCPUTemperatureAlarm,
itmex2atvNotifHWMonitorMainBoardTemperatureAlarm,
itmex2atvNotifHWMonitorLeftFanAlarm,
itmex2atvNotifHWMonitorRightFan2Alarm,
itmex2atvNotifHWMonitorBackplaneTemperatureAlarm
}
STATUS current
DESCRIPTION
"HW Monitor Alarms"
::= { itmex2atvNotificationsGroups 14 }
itmex2atvNotifGroupCommAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifCommAlarm,
itmex2atvNotifCommeth0Alarm,
itmex2atvNotifCommeth1Alarm,
itmex2atvNotifCommeth2Alarm,
itmex2atvNotifCommeth3Alarm,
itmex2atvNotifCommeth4Alarm,
itmex2atvNotifCommnetconfAlarm
}
STATUS current
DESCRIPTION
"Communications Alarms"
::= { itmex2atvNotificationsGroups 15 }
itmex2atvNotifGroupASIAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifASIAlarm
}
STATUS current
DESCRIPTION
"ASI Alarms"
::= { itmex2atvNotificationsGroups 16 }
itmex2atvNotifGroupInternalAlarm NOTIFICATION-GROUP
NOTIFICATIONS {
itmex2atvNotifInternalAlarm,
itmex2atvNotifInternalBackplaneAlarm,
itmex2atvNotifInternalReferenceClockAlarm,
itmex2atvNotifInternalUpConverterAlarm,
itmex2atvNotifInternalDownConverterAlarm,
itmex2atvNotifInternalMainboardAlarm,
itmex2atvNotifInternalBatteryAlarm,
itmex2atvNotifInternalFirmware1Alarm,
itmex2atvNotifInternalGNSSAlarm,
itmex2atvNotifInternalSatelliteAlarm,
itmex2atvNotifInternalEthAlarm,
itmex2atvNotifInternalPLLUnlockedAlarm,
itmex2atvNotifInternalCalibrationAlarm
}
STATUS current
DESCRIPTION
"Internal Alarms"
::= { itmex2atvNotificationsGroups 18 }