ModelNominal powerHousingStandard ConfigurationConfigurationDepth [cm]Standard Output Connector# Hot-plug PSUsNotes on PSUs# Transistor# FansStandard AC VoltageNotes on AC VoltageTyp. Power consumptionMax. Power consumption
ETX-0+20dBm2U Rack DrawerCompactCompact45N f-
01110-230VAC single phase
120VA150VA
ETX-3030W2U Rack DrawerCompactCompact45N f-
11110-230VAC single phase
200VA250VA
ETX-150150W2U Rack DrawerCompactCompact45N f-
11110-230VAC single phase
270VA320VA
ETX-600600W3U Rack DrawerCompactCompact457-16 DIN f1Option for redundant PSUs11 for chassis
 1 for amp stage
110-230VAC single phase
800VA900VA
ETX-10001kW3U Rack DrawerCompactCompact457-16 DIN f1Option for redundant PSUs11 for chassis
 1 for amp stage
230VAC single phasereduced power @110VAC, or full power with redundant PSU option1,3kVA1,5kVA
ETX-20002kW3U Rack DrawerCompactCompact457-16 DIN f2
22 for chassis
 2 for amp stage
230VAC single phasereduced power @110VAC2,7kVA3,1kVA
ETX-30003kW4U Rack DrawerCompactCompact707/8" EIA3
32230VAC single phase
400VAC three phase star
 230V three phase delta

4,0kVA4,5kVA
ETX-50005kW4U Rack DrawerCompactCompact707/8" EIA3Can work @ 4,9kW with only 2 PSUs52230VAC single phase
400VAC three phase star
 230V three phase delta

6,9kVA7,2kVA
ETX-1000010kW25U Rack Cabinet1 CU
1 Exciter
 2 Amplifiers
Rack cabinet1001+5/8" EIA3 on each PAEach PA can work @ 4,9kW with only 2 PSUs5 on each PA2 on each PA
 1 on rear side of the cabinet
400VAC three phase star
 230V three phase delta
other on request13,9kVA15,2kVA
ETX-1500015kW38URack Cabinet1 CU
1 Exciter
 3 Amplifiers
Rack cabinet1151+5/8" EIA3 on each PAEach PA can work @ 4,9kW with only 2 PSUs5 on each PA2 on each PA
 1 on rear side of the cabinet
400VAC three phase star
 230V three phase delta
other on request20,0kVA23,0kVA
ETX-2000020kW38URack Cabinet1 CU
1 Exciter
 4 Amplifiers
Rack cabinet1153+1/8" EIA3 on each PAEach PA can work @ 4,9kW with only 2 PSUs5 on each PA2 on each PA
 2 on rear side of the cabinet
400VAC three phase star
 230V three phase delta
other on request27,8kVA30,4kVA
ETX-2500025kW38URack Cabinet1 CU
1 Exciter
 5 Amplifiers
Rack cabinet1153+1/8" EIA3 on each PAEach PA can work @ 4,9kW with only 2 PSUs5 on each PA2 on each PA
 2 on rear side of the cabinet
400VAC three phase star
 230V three phase delta
other on request35,5kVA39,0kVA
ETX-3000030kW42URack Cabinet1 CU
1 Exciter
 6 Amplifiers
Rack cabinet1153+1/8" EIA3 on each PAEach PA can work @ 4,9kW with only 2 PSUs5 on each PA2 on each PA
 2 on rear side of the cabinet
400VAC three phase star
 230V three phase delta
other on request40,0kVA46,0kVA